Outcomes of Urethroplasty to Treat Urethral Strictures Arising From Artificial Urinary Sphincter Erosions and Rates of Subsequent Device Replacement
Notice bibliographique
Résumé
Objective To evaluate the success of urethroplasty for urethral strictures arising after erosion of an artificial urinary sphincter (AUS) and rates of subsequent AUS replacement. Patients and Methods From 2009-2016, we identified patients from the Trauma and Urologic Reconstruction Network of Surgeons and several other centers. We included patients with urethral strictures arising from AUS erosion undergoing urethroplasty with or without subsequent AUS replacement. We retrospectively reviewed patient demographics, history, stricture characteristics, and outcomes. Variables in patients with and without complications after AUS replacement were compared using chi-square test, independent samples t test, and Mann-Whitney U test when appropriate. Results Thirty-one men were identified with the inclusion criteria. Radical prostatectomy was the etiology of incontinence in 87% of the patients, and 29% had radiation therapy. Anastomotic (28) and buccal graft substitution (3) urethroplasty were performed. Follow-up cystoscopy was done in 28 patients (median 4.5 months, interquartile range [IQR]: 3-8) showing no urethral stricture recurrences. Median overall follow-up was 22.0 months (IQR: 15-38). In 27 men (87%), AUS was replaced at median of 6.0 months (IQR: 4-7) after urethroplasty. In 25 patients with >3 months of follow-up after AUS replacement, urethral complications requiring AUS revision or removal occurred in 9 patients (36%) and included subcuff atrophy (3) and erosion (6). Mean length of stricture was higher in patients who developed a complication after urethroplasty and AUS replacement (2.2 vs. 1.5 cm, P = .04). Conclusion In patients with urethral stricture after AUS erosion, urethroplasty is successful. However, AUS replacement after urethroplasty has a high erosion rate even in the short-term. To evaluate the success of urethroplasty for urethral strictures arising after erosion of an artificial urinary sphincter (AUS) and rates of subsequent AUS replacement. From 2009-2016, we identified patients from the Trauma and Urologic Reconstruction Network of Surgeons and several other centers. We included patients with urethral strictures arising from AUS erosion undergoing urethroplasty with or without subsequent AUS replacement. We retrospectively reviewed patient demographics, history, stricture characteristics, and outcomes. Variables in patients with and without complications after AUS replacement were compared using chi-square test, independent samples t test, and Mann-Whitney U test when appropriate. Thirty-one men were identified with the inclusion criteria. Radical prostatectomy was the etiology of incontinence in 87% of the patients, and 29% had radiation therapy. Anastomotic (28) and buccal graft substitution (3) urethroplasty were performed. Follow-up cystoscopy was done in 28 patients (median 4.5 months, interquartile range [IQR]: 3-8) showing no urethral stricture recurrences. Median overall follow-up was 22.0 months (IQR: 15-38). In 27 men (87%), AUS was replaced at median of 6.0 months (IQR: 4-7) after urethroplasty. In 25 patients with >3 months of follow-up after AUS replacement, urethral complications requiring AUS revision or removal occurred in 9 patients (36%) and included subcuff atrophy (3) and erosion (6). Mean length of stricture was higher in patients who developed a complication after urethroplasty and AUS replacement (2.2 vs. 1.5 cm, P = .04). In patients with urethral stricture after AUS erosion, urethroplasty is successful. However, AUS replacement after urethroplasty has a high erosion rate even in the short-term.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».