Shear Load Transfer for Corrosion Coated Clamped Joints
Notice bibliographique
Résumé
Rotorcraft transmission housings contain multiple joints that are typically held together by threaded fasteners. For many of these installations, the material surfaces are now coated with corrosion inhibitors that can change the strength of the joint. To identify these changes, Bell Helicopter has conducted coupon testing of coated materials in shear. Historically, the faying surfaces have been left bare with the perception that coatings would degrade the ability to transfer shear loads. Fastener and joint design has been based on assumed joint slip coefficients. A test effort to identify the shear load transfer characteristics of a clamped joint was undertaken. A double shear coupon test was used to measure the shear load capability of the clamped joint with bare material surfaces as well as with corrosion protection coated surfaces. Tests were run with calibrated bolt preloads to reduce variability. To simulate the gearbox temperature environment, the test coupons and mechanical grips were placed in an oven to maintain a temperature of 180°F. Testing showed that the addition of coating reduced the joint slip coefficient when compared to baseline bare materials.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».