A PRINCIPLE INVESTIGATION INTO THE FEASIBILITY OF USING MICROWAVE IMAGING TO MONITOR BONE HEALTH
Notice bibliographique
Résumé
INTRODUCTION Assessing bone health is of particular interest in age-associated disease and traumas such as osteoporosis, and fractures from extreme sports. Having tools that can safely and accurately assess bone health allows for the screening, diagnosis, and monitoring of disease or injury. The current gold standard for assessing bone health is high-resolution peripheral quantitative computed tomography (HR-pQCT) allowing direct three-dimensional (3D) visualization of bone. Recent evidence suggests microwave imaging can be a complementary medical imaging tool to HR-pQCT for dynamic assessment of full bone health [1]. Specifically, it was shown that microwave properties of cancellous bone are sensitive to physical changes in bone. However, this study was purely exploratory and provided no direct evidence for changes in dielectric properties with varying bone health. In this study, we aim to understand the interaction of electromagnetic waves with bone as a composite material, specifically the material anisotropy. Such information would be crucial to understanding how microwave measurements relate to the physical characteristics of the bone. METHODS Image data for the right and left tibia and radius of one female and two male subjects was acquired from HR-pQCT (XtremeCTII, Scanco Medical). The 3D image data was smoothed with a Gaussian filter (σ = 1.6) and segmented using histogram based segmentation. Cubes of edge length 82 voxels (5.002 mm) were extracted from the segmented images based on the bone center of geometry. The extracted cubes were imported into electromagnetic simulation software (SEMCAD X, Schmid & Partner Engineering AG). A parallel plate waveguide filled with air was excited with a Gaussian pulse polarized in the z-axis (f 0 = 6.5 GHz, BW = 11 GHz). The bone and marrow were assigned material properties from literature [2]. Resulting data was exported and processed using custom MATLAB scripts (R2013a, MathWorks). Three simulations were performed per image such that the electromagnetic wave was polarized in each of the three anatomical directions: anterior-posterior, medial-lateral, and proximal-distal. RESULTS The effective permittivity, e’ r , was calculated for each of the anatomical directions and plotted across the frequency range of the input signal. A representative plot for all images is shown in Figure 1. The effective permittivity for each orientation tend to vary around a common permittivity. DISCUSSION AND CONCLUSIONS The results presented here provide a rudimentary but novel insight into the anisotropic behaviour of bone at microwave frequencies. Furthermore, it presents a technique for 3D model acquisition and simulation of bone not yet present in literature. This technique will allow further exploration of the electromagnetic properties of bone such as a deeper insight into the anisotropic behaviour and development of a model for the effective medium of bone as a composite material. With such information, the microwave measurements of bone could be directly related to the bone’s physical properties. This would prove the potential of microwaves to assess bone health for disease or trauma and allow the development of in vivo imaging tools for assessing disease and trauma.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».