A Comparative Numerical Study on Heat Transfer Characteristics of a Shell and Tube Heat Exchanger with Segmental and Helical Baffles
Notice bibliographique
Résumé
As their name implies, Heat exchangers are used where is needed to heat transfer between a fluid and a solid object or two or more fluids in order to control the system temperature. In such devices, Heat transfer could be feasible by two ways: direct and indirect contact of fluids. Heat exchangers are very common in many industrial applications such as chemical and petrochemical plants, power stations, refrigeration and air conditioning systems, petroleum refineries, sewage treatment, etc. a good commonplace example of using heat exchangers in our daily life is the car radiator. Shell and tube heat exchangers are the most usual types of heat exchangers in industries which are robust and heavy duty because of their shape (they are typically suitable for higher pressure use). There are various types of baffles for shell and tube heat exchangers such as segmental (single and double segmented baffles), helical, disc and doughnut, etc. which are used to direct the fluid across the tube bundle, reinforce the endurance of long length tubes against sagging and decrease the system's vibration in total. In the recent years, some experimental and computational studies on heat transfer performance of various heat exchangers by changes in their physical specification or in thermo-physical properties of their working fluid were conducted by investigators [1-5]. In the present paper, a computational study of the comparison between using segmental (5 baffles with 1 mm thickness, 30 mm spacing and 50% baffle cut) and helical (with tilt angle of 45 o , baffle length of 115 mm and thickness of 1 mm) baffles on heat transfer rate of the same shell and tube counter-flow heat exchanger is carried out. The analysis have been accomplished for different Reynolds numbers (turbulent flow condition) of hot water in tubes side ranging from 4516 to 9032. In order to simulate, mesh and analyze the heat transfer apparatus, a commercial computational fluid dynamic (CFD) software (ANSYS Fluent) was adopted. The test section (shell & tube heat exchanger) with 174 mm length, consist of 9 stainless steel tubes which were installed with a triangular arrangement. The tubes' inner and outer diameters are 5 and 7 mm respectively. For shell side, the Inner and the outer diameters are around 33 and 39 mm respectively. The results demonstrate that the mean overall heat transfer coefficient of the shell and tube heat exchanger with segmental baffles is about 27% more than that of the same heat exchanger with helical baffle at defined velocity of hot fluid. Also it can be seen that the difference in the overall heat transfer coefficient of mentioned heat exchanger by using two types of baffles, rises with increment of Reynolds number and their values are specified around 13 and 39% at the minimum and the maximum Reynolds numbers, respectively. Finally, in order to evaluate the accuracy of the simulation, the numerical results were validated with Gnielinski [6] correlation (used for turbulent flow inside a tube) which was illustrated a good agreement between computational and predicted data.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».