Field evaluation of thermal and moisture response of highly insulated wood-frame walls
Notice bibliographique
Résumé
Over the years, the energy efficiency of the North American housing stock has significantly improved mainly due to higher insulation levels, more efficient windows and, more importantly, adoption of various energy efficiency measures by building codes. The increased insulation levels of building envelopes for homes leads to a multitude of opportunities as well as challenges. A major opportunity is to reduce heat losses and thereby significantly reducing the space heating loads. However, there are many challenges that necessitate changes in the current construction process, durability of products, and more importantly, the effect of higher insulation levels on the overall moisture performance and expected long-term performance of the building envelope. A major barrier to the uptake of highly insulated homes is the lack of proven evidence of reliable thermal and moisture performance of these homes as might be achieved in various climates of Canada. Following a survey of current construction practices, a set of six wall assemblies with different types of exterior insulation systems were chosen for field monitoring study undertaken in two separate Phases over a two year period in a test facility located in Ottawa, Canada. These wall assemblies ranged from total insulation value of RSI-4.8 to RSI 7.9 (R-27 to R-45). Full scale testing included year-round performance monitoring. These wall specimens were installed in a side-by-side test bay and were subjected to local climate conditions of Ottawa, Canada; on the interior of the specimens conditions were nominally maintained at 20°C and 50% RH. This paper provides results of field trials of the six wall assemblies in terms of their hygrothermal performance and risk for condensation over a two year period of operation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».