Continuous optimization of cardiac resynchronization therapy reduces atrial fibrillation in heart failure patients: Results of the Adaptive Cardiac Resynchronization Therapy Trial
Notice bibliographique
Résumé
BackgroundData from randomized trials have suggested a modest or no effect of conventional cardiac resynchronization therapy (convCRT) on the incidence of atrial fibrillation (AF). AdaptivCRT (aCRT, Medtronic, Mounds View, MN) is a recently described algorithm for synchronized left ventricular (LV) pacing and continuous optimization of cardiac resynchronization therapy (CRT).ObjectiveWe compared the long-term effects of aCRT with convCRT pacing on the incidence of AF.MethodsThe Adaptive CRT trial randomized CRT-defibrillator (CRT-D)–indicated patients (2:1) to receive either aCRT or convCRT pacing. The aCRT algorithm evaluates intrinsic conduction every minute, providing LV-only pacing during normal atrioventricular (AV) conduction and AV and ventriculoventricular timing adjustments during prolonged AV conduction. The primary outcome of this subanalysis was an episode of AF >48 consecutive hours as detected by device diagnostics.ResultsOver a follow-up period with a mean and standard deviation of 20.2 ± 5.9 months, 8.7% of patients with aCRT and 16.2% with convCRT experienced the primary outcome (hazard ratio [HR] = 0.54; 95% confidence interval [CI] = 0.31–0.93; P = .03). In patients with prolonged baseline AV, the incidence of the primary outcome was 12.8% in patients randomized to aCRT compared with 27.4% in convCRT patients (HR = 0.45; 95% CI = 0.24–0.85; P = .01). Also, patients with AF episodes adjudicated as clinical adverse events were less common with aCRT (4.3%) than with convCRT (12.7%) (HR = 0.39; 95% CI = 0.19–0.79; P = .01).ConclusionPatients receiving aCRT had a reduced risk of AF compared with those receiving convCRT. Most of the reduction in AF occurred in subgroups with prolonged AV conduction at baseline and with significant left atrial reverse remodeling. Data from randomized trials have suggested a modest or no effect of conventional cardiac resynchronization therapy (convCRT) on the incidence of atrial fibrillation (AF). AdaptivCRT (aCRT, Medtronic, Mounds View, MN) is a recently described algorithm for synchronized left ventricular (LV) pacing and continuous optimization of cardiac resynchronization therapy (CRT). We compared the long-term effects of aCRT with convCRT pacing on the incidence of AF. The Adaptive CRT trial randomized CRT-defibrillator (CRT-D)–indicated patients (2:1) to receive either aCRT or convCRT pacing. The aCRT algorithm evaluates intrinsic conduction every minute, providing LV-only pacing during normal atrioventricular (AV) conduction and AV and ventriculoventricular timing adjustments during prolonged AV conduction. The primary outcome of this subanalysis was an episode of AF >48 consecutive hours as detected by device diagnostics. Over a follow-up period with a mean and standard deviation of 20.2 ± 5.9 months, 8.7% of patients with aCRT and 16.2% with convCRT experienced the primary outcome (hazard ratio [HR] = 0.54; 95% confidence interval [CI] = 0.31–0.93; P = .03). In patients with prolonged baseline AV, the incidence of the primary outcome was 12.8% in patients randomized to aCRT compared with 27.4% in convCRT patients (HR = 0.45; 95% CI = 0.24–0.85; P = .01). Also, patients with AF episodes adjudicated as clinical adverse events were less common with aCRT (4.3%) than with convCRT (12.7%) (HR = 0.39; 95% CI = 0.19–0.79; P = .01). Patients receiving aCRT had a reduced risk of AF compared with those receiving convCRT. Most of the reduction in AF occurred in subgroups with prolonged AV conduction at baseline and with significant left atrial reverse remodeling.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».