Comparing a novel hand held device (Peritron+) to standard urodynamics in measuring intravesical pressure
Notice bibliographique
Résumé
Aims Peritron+ is a new handheld device, which can be attached to a urethral catheter to measure intravesical pressures (Pves). The goal of this study was to assess if Pves recorded by standard urodynamics (UDs) are comparable to those recorded by the Peritron+. Methods Patients with voiding dysfunction and an indication for UD underwent measurement of Pves with nonvideo UD and Peritron+. Pves were recorded at volumes of 50, 100, and 200 mL for the supine and sitting positions. A failure of the Peritron+ was considered to be a discrepancy of Pves values >3 cmH2O between Peritron+ and UD recordings. Two‐way ANOVA was used to assess for statistical significance. P‐values < 0.05 were considered significant. Results Ten female patients, mean age 51 years old, were enrolled in the study. The difference in Pves measurements between Peritron+ and UD were ≤3 cmH2O at all bladder volumes measured in a supine and sitting positions. There were no adverse events and there were no malfunctions of the Peritron+ device during the study. Conclusions Peritron+ handheld device accurately assessed Pves at different intravesical volumes when compared to UD measurements. The Peritron+ is a simple and safe device, which can be used in the office by a clinician and at home by a patient to monitor Pves and help to select patients who may require standard UD re‐evaluation. This will be a valuable tool in managing patients with neurogenic and nonneurogenic bladders who are at a risk of upper urinary tract deterioration.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,005 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».