Intracardiac ablation for atrioventricular nodal reentry tachycardia using a 6 mm distal electrode cryoablation catheter: Prospective, multicenter, North American study (ICY‐AVNRT STUDY)
Notice bibliographique
Résumé
INTRODUCTION: Radiofrequency (RF) ablation is effective for slow pathway ablation, but carries a risk of inadvertent AV block requiring permanent pacing. By comparison, cryoablation with a 4-mm distal electrode catheter has not been reported to cause permanent AV block but has been shown to be less effective than RF ablation. We sought to define the safety and efficacy of a 6-mm distal electrode cryoablation catheter for slow pathway ablation in patients with atrioventricular nodal reentry tachycardia (AVNRT). METHODS AND RESULTS: Twenty-six U.S. and eight Canadian centers participated in the study. Patients with supraventricular tachycardia (SVT) thought likely to be AVNRT were enrolled. If AVNRT was inducible and confirmed to be the clinical SVT, then the slow pathway was targeted with a cryoablation catheter using a standardized protocol of best practices. Acute success was defined as inducibility of no more than one echo beat after cryoablation. Primary efficacy was defined as acute success and the absence of documented recurrent AVNRT over 6 months of follow-up. Primary safety was a composite of serious procedure-related adverse events and/or device-related complications. Note that 397 subjects met enrollment criteria after the EP study and received cryoablation. Mean ablation procedure duration (including a waiting period) was 89 ± 40 minutes, and mean fluoroscopy time was 4.8 ± 5.9 minutes. Isoproterenol was administered before cryoablation in 53% and after the last lesion in 85% of cases. Acute procedural success was realized in 95% (378 of 397) of subjects. No subject received a permanent pacemaker due to AV block. The slow pathway could not be ablated in 19 subjects, including: 12 due to inefficacy, 2 due to transient AV block, and 5 due to both inefficacy and transient AV block. RF ablation was used in the same procedure in 11 of 19 failed subjects, and was ineffective in 3 subjects. Among the group with acute success, 10 subjects (2.7%) had documented recurrent AVNRT over the 6-month follow-up period, and all occurred within 3 months of the index cryoablation. Serious procedure-related adverse events occurred in 4 subjects (1.0%), including one each: tamponade, pulmonary embolism, femoral vein hemorrhage, and diagnostic EP catheter knotting. None of these serious adverse events were related to use of the cryoablation catheter. Overall, 93% of subjects had successful slow pathway ablation at 6 months with the study cryoablation catheter. CONCLUSIONS: Cryoablation for AVNRT using a focal 6-mm catheter was safe and effective. It resulted in a low risk of recurrence over 6 months of follow-up with no incidence of AV block requiring permanent pacing.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,004 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».