Hands-on-experience on seismic retrofit in four different countries
Notice bibliographique
Résumé
There are various different seismic vulnerability assessment procedures and seismic retrofit methods that have been applied to existing buildings in seismic regions. After the analytical assessment and design phase, it is of critical importance that the retrofit design is properly applied on-site. Conventional parties such as local authorities, construction culture, construction companies, quality of workmanship and availability of materials play a crucial role in the construction of seismic resistant buildings and in the selection of retrofit method and application. Furthermore there is a lack of experience on the performance of buildings subjected to earthquakes. Authors assessed and retrofitted eight reinforced concrete buildings and one masonry building from one to six stories in Nepal, Djibouti, Turkmenistan and Hati, respectively, in 2011 Retrofitted buildings in Nepal were subjected to 7.8 magnitude earthquake in April 2015, which gave authors the opportunity to document the seismic performance. This paper summarizes the hands-on-experience gained from four different seismic assessment and retrofitted projects conducted in four different countries. Performance of the retrofitted buildings subjected to a 7.8 magnitude earthquake and difficulties in the application of retrofit are present.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».