Feasibility of extravascular pacing with a novel substernal electrode configuration: The Substernal Pacing Acute Clinical Evaluation study
Notice bibliographique
Résumé
BackgroundSubcutaneous implantable cardioverter-defibrillators provide an alternative to transvenous defibrillation but require higher shock outputs and offer no antitachycardia pacing. The Substernal Pacing Acute Clinical Evaluation (SPACE) study evaluated the feasibility of pacing from an extravascular substernal location.ObjectivesThe primary purpose of the SPACE study was to characterize pacing from the substernal space. Secondary objectives included evaluating extracardiac stimulation and recording electrograms.MethodsThe SPACE study prospectively evaluated the feasibility of pacing with a commercially available electrophysiology catheter acutely implanted in the substernal space via minimally invasive subxiphoid access. Pacing data were collected in ≥7 vectors using constant current stimulation up to 20 mA and pulse width up to 10 ms.ResultsCatheter placement was successful in all 26 patients who underwent the procedure, with a mean placement time of 11.7 ± 10.1 minutes. Eighteen patients (69%) had successful ventricular capture in ≥1 tested vector. The mean pacing threshold at a pulse width of 10 ms was 7.3 ± 4.2 mA across all vectors (5.8 ± 4.4 V). Failed capture was generally associated with suboptimal catheter placement or presumed air ingression. A low level of extracardiac stimulation was observed in 1 patient. The mean R-wave amplitude ranged from 2.98 to 4.11 mV in the unipolar configuration and from 0.83 to 3.95 mV in the bipolar configuration.ConclusionThe data from the SPACE study demonstrate that pacing is feasible from the extravascular substernal location. A substernal electrode configuration has the potential to provide pacing in a future extravascular device without need for intracardiac hardware placement. Subcutaneous implantable cardioverter-defibrillators provide an alternative to transvenous defibrillation but require higher shock outputs and offer no antitachycardia pacing. The Substernal Pacing Acute Clinical Evaluation (SPACE) study evaluated the feasibility of pacing from an extravascular substernal location. The primary purpose of the SPACE study was to characterize pacing from the substernal space. Secondary objectives included evaluating extracardiac stimulation and recording electrograms. The SPACE study prospectively evaluated the feasibility of pacing with a commercially available electrophysiology catheter acutely implanted in the substernal space via minimally invasive subxiphoid access. Pacing data were collected in ≥7 vectors using constant current stimulation up to 20 mA and pulse width up to 10 ms. Catheter placement was successful in all 26 patients who underwent the procedure, with a mean placement time of 11.7 ± 10.1 minutes. Eighteen patients (69%) had successful ventricular capture in ≥1 tested vector. The mean pacing threshold at a pulse width of 10 ms was 7.3 ± 4.2 mA across all vectors (5.8 ± 4.4 V). Failed capture was generally associated with suboptimal catheter placement or presumed air ingression. A low level of extracardiac stimulation was observed in 1 patient. The mean R-wave amplitude ranged from 2.98 to 4.11 mV in the unipolar configuration and from 0.83 to 3.95 mV in the bipolar configuration. The data from the SPACE study demonstrate that pacing is feasible from the extravascular substernal location. A substernal electrode configuration has the potential to provide pacing in a future extravascular device without need for intracardiac hardware placement.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».