MétaCan
Menu
Retour à la cohorte
Enregistrement W2780585336 · doi:10.14288/1.0223405

Force based design guideline for timber-steel hybrid structures : steel moment resisting frames with CLT infill walls

2017· article· en· W2780585336 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

aboutLe titre ou le résumé porte un signal canadien du lexique géographique.
no affAucune affiliation canadienne : ce travail est invisible pour une base fondée sur la seule affiliation.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Notice bibliographique

RevuecIRcle (University of British Columbia) · 2017
Typearticle
Langueen
DomaineEngineering
ThématiqueCivil and Structural Engineering Research
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésInfillStructural engineeringMoment (physics)EngineeringGeologyForensic engineering

Résumé

récupéré en direct d'OpenAlex

Provincial code changes have been made to allow construction of light wood-frame buildings up to 6 storeys in order to satisfy the urban housing demand in western Canadian cities. It started in 2009 when the BC Building Code was amended to increase the height limit for wood-frame structures from four to six. Recently, provinces of Quebec, Ontario and Alberta followed suit. While wood-frame construction is limited to six storeys, some innovative wood-hybrid systems can go to greater heights. In this report, a feasibility study of timber-based hybrid buildings is described as carried out by The University of British Columbia (UBC) in collaboration with FPInnovations. This project, funded through BC Forestry Innovation Investment's (FII) Wood First Program, had an objective to develop design guidelines for a new steel–timber hybrid structural system that can be used as a part of the next generation "steel-timber hybrid structures" that is limited in scope to 20 storey office or residential buildings. The steel-timber hybrid structure incorporates Cross Laminated Timber (CLT) infill walls in the steel moment resisting frames. This structure is aimed to couple strong, ductile steel moment resisting frames with lighter and stiff CLT infill walls. L-shaped steel bracket connectors were proposed to connect the steel frames to the CLT panels. Thorough experimental studies have been carried out on the seismic behaviour of the bracket connections at UBC and FPInnovations for the past four years. These connections are bolted to the steel frame and nailed to the CLT infill walls. Moreover, the provided brackets ensure full confinement between the structural elements and energy dissipation under intense seismic action. The National Building Code of Canada (NBCC) allows an Equivalent Static Force Procedure (ESFP) design method to be used with appropriate overstrength and ductility factors for the seismic design of structures. However, NBCC (NRC 2010) does not have the appropriate overstrength and ductility factors to design the proposed hybrid structure. Thus, in this report, overstrength and ductility factors were quantified analytically. A robust finite element model of the hybrid structure that accounts for the CLT panel and frame interactions was developed in OpenSees (Open System for Earthquake Engineering Simulation) (Mazzoni et al. 2006) and used for the analytical investigation. Initially for buildings designed with an Rd = 2 and Ro = 1.5, 18 different hybrid buildings were modeled and subjected to monotonic static pushover loading by varying the following modeling variables: building height (1, 3, 6, 9, 12, 15 and 20 storey), CLT infill configuration (one-bay infilled and two-bay infilled), connection bracket spacing (800 mm), and ductility class (ductile D and limited ductile LD). In order to have a non-conservative and economical design, 3-, 6-, and 9-storey hybrid buildings were designed using Rd = 4 and Ro = 1.5. A nonlinear static pushover analysis has been performed to validate the overstrength factors of the hybrid buildings under consideration. In order to check the FEMA P695 (FEMA 2009) acceptable failure probabilities and collapse margin ratios, Nonlinear Time History Analysis (NLTHA) and Incremental Dynamic Analysis (IDA) were carried out using 60 ground motion records. Ground motions were selected and scaled for the city of Vancouver by considering site class C of NBCC 2010 (NRC 2010). Due to the complexity and the contributions of sub-crustal and subduction type earthquakes to the total seismic hazard, the traditional FEMA P695 (FEMA 2009) was not utilized in the ground motion selection and scaling. Therefore, a new ground motion selection criteria that specifically incorporates the seismicity of Vancouver, Canada, were utilized for this project. In the IDA, conservative collapse criteria have been followed to define the dynamic instability of the building. In this approach, structural hardening was only considered for interstorey drift values less than 10% and the lowest spectral acceleration value was considered as a limit state point. Analysis was done by a high performance computational method using 200 clusters of computers at The University of British Columbia research computing service center. The results show that the presence of CLT infill walls significantly affects the systems overstrength value, by sacrificing ductility. From this research, it can be concluded that an overstrength factor of Ro = 1.5 and a ductility factor of Rd = 4 showed acceptable and economical design of the proposed hybrid structure.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,711
Score d'incertitude au seuil0,997

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0010,000
Communication savante0,0000,000
Science ouverte0,0010,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,014
Tête enseignante GPT0,201
Écart entre enseignants0,187 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle