A New Device for Securing Sternal Wires after Median Sternotomy
Notice bibliographique
Résumé
OBJECTIVE: Morbidity due to sternotomy continues to be a significant clinical problem. Poor approximation of the sternum may lead to complications such as sternal dehiscence, infection, and pain. A device to assist in tensioning and twisting standard steel wires during sternal closure has been developed (TORQ sternal closure device). Manually tightened interrupted wire closures were compared with those tightened and secured with the aid of the device. Performance of the device was assessed clinically. METHODS: Four cardiovascular surgeons performed manual and device-assisted closures on a biofidelic model. Closure force was measured to determine the residual force and its intraoperator variation. A retrospective review of patients treated before and after the introduction of the device was conducted. Predicted and actual outcomes were compared for the two groups (manual closure and device-assisted closure). RESULTS: Biomechanical testing measured a 75% increase in residual closure force (P < 0.001) and a significant reduction in the variability of the closure force (P = 0.045) for device-assisted closures compared with manual closures. In the retrospective study, 3 of 173 manually closed patients had sterile sternal dehiscence and 1 of 173 had a deep sternal wound infection. In the device closure group, 2 of 127 had a sterile sternal dehiscence and no deep sternal wound infections were reported. No other device-related serious adverse events were reported. CONCLUSIONS: Biomechanical data showed stronger, more consistent closure forces with the device. The retrospective data attest to the performance of the device.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,002 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».