Comparison of voltage control methods in distribution systems using Q-V based PI and droop controls of solar inverters
Notice bibliographique
Résumé
The increasing penetration of photovoltaic power generation in distribution systems causes serious voltage management issues. To mitigate the voltage variations due to solar generation intermittency, this paper introduces a PI-based reactive power control method of PV inverters. The proposed PI controller adjusts the reactive power injection of the solar inverters dynamically to drive the voltage at the Point of Common Coupling (PCC) to a target value. The simulation studies are performed to evaluate the proposed PI-based reactive power control using the IEEE 34 test feeder for a 24-hour period in OpenDSS and Matlab. The performance of the proposed PI controller is compared to the conventional PV inverter controls with no reactive power generation and with the Q-V-based droop control at different penetration levels. The case studies demonstrate that the proposed PI-based voltage control method reduces effectively the voltage deviations at the PCC of the PV inverters. The voltage profiles under the proposed PI controller have narrower variation bands compared with the conventional PV reactive power control methods particularly at high penetration levels of solar generation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».