Utilizing tension reduction in a dielectric elastomer actuator to produce compression for physiological application
Notice bibliographique
Résumé
A common prophylaxis against peripheral vascular diseases utilizes pneumatic active compression systems. Although effective, traditional active compression systems require the use of an air compressor and pump and are, therefore, ill-suited for ambulatory use. The current work introduces a novel approach to developing an ambulatory smart material–based active compression system. The actuation system is composed of a belt-like mechanism connected in conjunction with a multi-layered dielectric elastomer actuator. The belt mechanism allows compression to be applied directly with voltage application. By doing so, the proposed design limits the period during which the actuator should be charged and improves system power efficiency and lifetime. An analytical model which defines the pre-compression exerted by the actuation system before voltage application is presented and validated experimentally. Experimental results for the belt mechanism characterization, dielectric elastomer actuator characterization and actuation system testing are presented. Through experimental testing, it is shown that the initial pre-compression can be fine-tuned by varying the parameters of the system as defined in the analytical model, and that the pre-compression has little effect on the consequent actuation output amplitudes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».