Influence of High pH on the Organization of Acetonitrile at the Silica/Water Interface Studied by Sum Frequency Generation Spectroscopy
Notice bibliographique
Résumé
The acetonitrile–water mixture is one of the most commonly used solvents in hydrophilic interaction chromatography, which contains silica as the solid phase. As such, the silica/acetonitrile–water interface plays a large role in the separation of compounds. Varying the pH is one way to influence retention times, particularly of ionizable solutes, yet the influence of high pH is often unpredictable. To determine how the structure of this interface changes with pH, we utilized the surface specific technique sum frequency generation (SFG). Previous SFG studies at neutral pH have suggested the existence of acetonitrile bilayers at the aqueous silica interface even at low acetonitrile mole fractions. Here we find that the SFG signal from 2900 to 3040 cm–1 at the silica/acetonitrile–water interface increased as we adjusted the aqueous pH from near neutral to high values. This increase in signal was attributed to a greater amount of aligned water which is consistent with an increase in silica surface charge at high pH. In contrast, complementary measurements of the silica/acetonitrile–deuterium oxide interface revealed that the acetonitrile methyl mode nearly vanished as the aqueous pH was increased. This loss of methyl mode signal is indicative of a decrease in the number density of acetonitrile molecules at the interface, as orientation analysis indicates no significant change in the net orientation of the outer leaflet of the acetonitrile bilayer over the pH range studied.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».