Vasoconstrictor stimulus determines the functional contribution of myoendothelial feedback to mesenteric arterial tone
Notice bibliographique
Résumé
Key points In isolated resistance arteries, endothelial modulation of vasoconstrictor responses to α 1 ‐adrenoceptor agonists occurs via a process termed myoendothelial feedback: localized inositol trisphosphate (InsP 3 )dependent Ca 2+ transients activate intermediate conductance Ca 2+ activated K + (IK Ca ) channels, hyperpolarizing the endothelial membrane potential to limit further reductions in vessel diameter. We demonstrate that IK Ca channel‐mediated myoendothelial feedback limits responses of isolated mesenteric arteries to noradrenaline and nerve stimulation, but not to the thromboxane A 2 mimetic U46619 or to increases in intravascular pressure. In contrast, in the intact mesenteric bed, although responses to exogenous noradrenaline were limited by IK Ca channel‐mediated myoendothelial feedback, release of NO and activation of endothelial small conductance Ca 2+ activated K + (SK Ca ) channels in response to increases in shear stress appeared to be the primary mediators of endothelial modulation of vasoconstriction. We propose that (1) the functional contribution of myoendothelial feedback to arterial tone is determined by the nature of the vasoconstrictor stimulus, and (2) although IK Ca channel‐mediated myoendothelial feedback may contribute to local control of arterial diameter, in the intact vascular bed, increases in shear stress may be the major stimulus for engagement of the endothelium during vasoconstriction. Abstract Constriction of isolated resistance arteries in response to α 1 ‐adrenoceptor agonists is limited by reciprocal engagement of inhibitory endothelial mechanisms via myoendothelial feedback. In the current model of feedback, agonist stimulation of smooth muscle cells results in localized InsP 3 dependent Ca 2+ transients that activate endothelial IK Ca channels. The subsequent hyperpolarization of the endothelial membrane potential then feeds back to the smooth muscle to limit further reductions in vessel diameter. We hypothesized that the functional contribution of InsP 3 –IK Ca channel‐mediated myoendothelial feedback to limiting arterial diameter may be influenced by the nature of the vasoconstrictor stimulus. To test this hypothesis, we investigated the functional role of myoendothelial feedback in modulating responses of rat mesenteric resistance arteries to the adrenoceptor agonist noradrenaline, the thromboxane A 2 mimetic U46619, increases in intravascular pressure and stimulation of perivascular sympathetic nerves. In isolated arteries, responses to noradrenaline and stimulation of sympathetic nerves, but not to U46619 and increases in intravascular pressure, were modulated by IK Ca channel‐dependent myoendothelial feedback. In the intact mesenteric bed perfused under conditions of constant flow, responses to exogenous noradrenaline were modulated by myoendothelial feedback, but shear stress‐induced release of NO and activation of endothelial SK Ca channels appeared to be the primary mediators of endothelial modulation of vasoconstriction to agonists and nerve stimulation. Thus, we propose that myoendothelial feedback may contribute to local control of diameter within arterial segments, but at the level of the intact vascular bed, increases in shear stress may be the major stimulus for engagement of the endothelium during vasoconstriction.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».