MétaCan
Menu
Retour à la cohorte
Enregistrement W2805014542 · doi:10.1002/14651858.cd013031.pub2

Chest ultrasonography versus supine chest radiography for diagnosis of pneumothorax in trauma patients in the emergency department

2020· review· en· W2805014542 sur OpenAlexaff
Kenneth K. Chan, Daniel Joo, Andrew D. McRae, Yemisi Takwoingi, Zahra Premji, Eddy Lang, Abel Wakai

Notice bibliographique

RevueCochrane Database of Systematic Reviews · 2020
Typereview
Langueen
DomaineMedicine
ThématiqueUltrasound in Clinical Applications
Établissements canadiensUniversity of Calgary
Organismes subventionnairesnon disponible
Mots-clésSupine positionMedicinePneumothoraxEmergency departmentRadiographyRadiologyUltrasonographyFocused assessment with sonography for traumaSurgeryBluntNursing

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Chest X-ray (CXR) is a longstanding method for the diagnosis of pneumothorax but chest ultrasonography (CUS) may be a safer, more rapid, and more accurate modality in trauma patients at the bedside that does not expose the patient to ionizing radiation. This may lead to improved and expedited management of traumatic pneumothorax and improved patient safety and clinical outcomes. OBJECTIVES: To compare the diagnostic accuracy of chest ultrasonography (CUS) by frontline non-radiologist physicians versus chest X-ray (CXR) for diagnosis of pneumothorax in trauma patients in the emergency department (ED). To investigate the effects of potential sources of heterogeneity such as type of CUS operator (frontline non-radiologist physicians), type of trauma (blunt vs penetrating), and type of US probe on test accuracy. SEARCH METHODS: We conducted a comprehensive search of the following electronic databases from database inception to 10 April 2020: Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, MEDLINE, Embase, Cumulative Index to Nursing and Allied Health Literature (CINAHL) Plus, Database of Abstracts of Reviews of Effects, Web of Science Core Collection and Clinicaltrials.gov. We handsearched reference lists of included articles and reviews retrieved via electronic searching; and we carried out forward citation searching of relevant articles in Google Scholar and looked at the "Related articles" on PubMed. SELECTION CRITERIA: We included prospective, paired comparative accuracy studies comparing CUS performed by frontline non-radiologist physicians to supine CXR in trauma patients in the emergency department (ED) suspected of having pneumothorax, and with computed tomography (CT) of the chest or tube thoracostomy as the reference standard. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data from each included study using a data extraction form. We included studies using patients as the unit of analysis in the main analysis and we included those using lung fields in the secondary analysis. We performed meta-analyses by using a bivariate model to estimate and compare summary sensitivities and specificities. MAIN RESULTS: We included 13 studies of which nine (410 traumatic pneumothorax patients out of 1271 patients) used patients as the unit of analysis; we thus included them in the primary analysis. The remaining four studies used lung field as the unit of analysis and we included them in the secondary analysis. We judged all studies to be at high or unclear risk of bias in one or more domains, with most studies (11/13, 85%) being judged at high or unclear risk of bias in the patient selection domain. There was substantial heterogeneity in the sensitivity of supine CXR amongst the included studies. In the primary analysis, the summary sensitivity and specificity of CUS were 0.91 (95% confidence interval (CI) 0.85 to 0.94) and 0.99 (95% CI 0.97 to 1.00); and the summary sensitivity and specificity of supine CXR were 0.47 (95% CI 0.31 to 0.63) and 1.00 (95% CI 0.97 to 1.00). There was a significant difference in the sensitivity of CUS compared to CXR with an absolute difference in sensitivity of 0.44 (95% CI 0.27 to 0.61; P < 0.001). In contrast, CUS and CXR had similar specificities: comparing CUS to CXR, the absolute difference in specificity was -0.007 (95% CI -0.018 to 0.005, P = 0.35). The findings imply that in a hypothetical cohort of 100 patients if 30 patients have traumatic pneumothorax (i.e. prevalence of 30%), CUS would miss 3 (95% CI 2 to 4) cases (false negatives) and overdiagnose 1 (95% CI 0 to 2) of those without pneumothorax (false positives); while CXR would miss 16 (95% CI 11 to 21) cases with 0 (95% CI 0 to 2) overdiagnosis of those who do not have pneumothorax. AUTHORS' CONCLUSIONS: The diagnostic accuracy of CUS performed by frontline non-radiologist physicians for the diagnosis of pneumothorax in ED trauma patients is superior to supine CXR, independent of the type of trauma, type of CUS operator, or type of CUS probe used. These findings suggest that CUS for the diagnosis of traumatic pneumothorax should be incorporated into trauma protocols and algorithms in future medical training programmes; and that CUS may beneficially change routine management of trauma.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,014
score de la tête « metaresearch » (Gemma)0,092
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,014
Score d'incertitude au seuil0,072

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0140,092
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0070,006
Bibliométrie0,0050,006
Études des sciences et des technologies0,0010,001
Communication savante0,0020,002
Science ouverte0,0020,001
Intégrité de la recherche0,0020,001
Charge utile insuffisante (le modèle a refusé de juger)0,0050,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,170
Tête enseignante GPT0,425
Écart entre enseignants0,255 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeRevue systématique
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations146
Publié2020
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueCochrane Database of Systematic ReviewsMême sujetUltrasound in Clinical ApplicationsTravaux en français237 207