Automated hand hygiene monitoring system using imagery and bluetooth low energy sensors
Notice bibliographique
Résumé
This thesis designs and implements a hand hygiene monitoring system using Bluetooth low energy and imagery sensors. As the cost of treating healthcare-associated infections increases, the need for monitoring and improving hand hygiene compliance percentages for healthcare providers increases. Several techniques for hand hygiene compliance monitoring exist, but it was found that electronic automated systems are the most reliable solution because they provide more accurate continuous compliance measurements for lower cost. Other similar systems based on a variety of technologies exist, however, they are either uniquely evidence based, so that they capture hygiene moments and apply a statistical model for hygiene opportunities, and they, therefore, do not provide real-time information; or they require human interference to determine compliance rendering them not fully automated. In this thesis, available monitoring techniques, focusing on automated electronic systems, are first introduced. Then, a novel automated hand hygiene monitoring system, capable of capturing hygiene moments with more than 90% precision, is proposed. The proposed system was first tested in a lab environment with private rooms setup, the system was also tested in semi-private rooms setup and then implemented in the Hematology and Oncology Department at the Health Sciences Center of Eastern Health for a pilot study. The study showed a high correlation between the compliance rates calculated by the proposed system compared to the compliance rates found by direct observers.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,004 | 0,002 |
| Études des sciences et des technologies | 0,002 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».