Concept to Commercialization of an Artifact for Evaluating Three-Dimensional Imaging Systems per ASTM E3125-17
Notice bibliographique
Résumé
The relative-range error test is one of several tests described in the ASTM E3125-2017 standard for performance evaluation of spherical coordinate three-dimensional (3D) imaging systems such as terrestrial laser scanners (TLS). We designed a new artifact, called the plate-sphere target, that allows the realization of the relative-range error tests quickly and efficiently without the need for alignment at each position of the test.Use of a simple planar/plate target requires careful alignment of the target at each position of the relative-range error test, which is labor-intensive and time-consuming. This new artifact significantly reduces the time required to perform the test, from a matter of about 2 h to less than 30 min while resulting in similar test uncertainty values.The plate-sphere target was conceived and initially developed at the National Institute of Standards and Technology (NIST), improved based on feedback from collaborators at the National Research Council (NRC) of Canada and TLS manufacturers, and commercialized by Bal-tec Inc.This new artifact will save users and manufacturers of TLSs considerable time and money.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,015 | 0,015 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,004 | 0,003 |
| Études des sciences et des technologies | 0,001 | 0,003 |
| Communication savante | 0,004 | 0,004 |
| Science ouverte | 0,004 | 0,004 |
| Intégrité de la recherche | 0,002 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,008 | 0,007 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».