Feedback Control of Functional Electrical Stimulation for 2-D Arm Reaching Movements
Notice bibliographique
Résumé
Functional electrical stimulation (FES) can be used as a neuroprosthesis in which muscles are stimulated by electrical pulses to compensate for the loss of voluntary movement control. Modulating the stimulation intensities to reliably generate movements is a challenging control problem. This paper introduces a feedback controller for a multi-muscle FES system to control hand movements in a 2-D (table-top) task space. This feedback controller is based on a recent human motor control model, which uses muscle synergies to simplify its calculations and improve the performance. This synergy-based controller employs direct relations between the muscle synergies and the produced hand force, therefore allowing for the real-time calculation of six muscle stimulation levels required to reach an arbitrary target. The experimental results show that this control scheme can perform arbitrary point-to-point reaching tasks in the 2-D task space in real time, with an average of ~2 cm final hand position error from the specified targets. The success of this prototype demonstrates the potential of the proposed method for the feedback control of functional tasks with FES.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».