AT1R Antibody Assessment
Notice bibliographique
Résumé
Introduction The angiotensin II type 1 receptor (AT1R) is a G-protein-coupled receptor that is expressed on vascular endothelium. It can signal cell growth and proliferation, fibrosis, and vascular remodeling. AT1R antibodies are being increasingly studied to examine their relevance in transplantation. The frequency and impact of AT1R antibodies in pediatric heart transplantation has not been well studied. Our aim is to measure the frequency of AT1R antibodies in this patient population as well as pediatric controls and to assess for non-specific reactivity in this assay. Methods We included 42 patients (n=154 samples) for whom pre- and post-transplant sera and HLA antibody data were available. AT1R antibody levels were measured by a commercially available ELISA test (distributed by One Lambda ThermoFisher). Samples were tested/interpreted as per product insert. Results were negative under 10 U/mL and positive over 17 U/mL. Age-matched, sex-balanced, non-transplant controls (n=27) were collected from the local cardiac-catheterization laboratory. A subset of samples with positive results (n=52 sera from 20 patients) as well as the assay’s positive control were re-tested following adsorption with Adsorb Out (One Lambda ThermoFisher.). Figure 1 details the samples and testing methodology. Analysis was performed using GraphPad.Results No significant difference was observed between patient and control AT1R antibody levels (Figure 2). Values over the test method upper threshold (40 U/mL) were detected in 38% of patient sera. Adsorbed sera had significantly decreased AT1R values vs non adsorbed sera (Figure 3A). There was no significant change from pre- to post-transplant AT1R antibody detected overall (Figures 3B and 3C). In the UN-adsorbed sera, 57% of the pre-transplant sera and 64% of the post-transplant sera tested positive for AT1R antibody; 58% and 78% were positive above the 40U/mL threshold, respectively. In contrast, In the ADSORBED sera, 21% of the pre-transplant sera and 15% of the post-transplant sera tested positive for AT1R antibody; 29% and 20% were positive above the 40U/mL threshold, respectively.Conclusion Pediatric heart transplant patients appear to yield false positive results in this AT1R assay. This problem may be overcome by adsorbing for non-specific reactivity. Non-specific binding is a known concern in immunoassays such as ELISA. Typically, controls are included in these assays such as a ‘no antigen’ well and/or absorption steps are performed. This assay is lacking an essential control that is required by clinical laboratory standards. The pediatric heart transplant population may have especially high levels of non-specific reactivity in immunoassays due to the high frequency of thymectomy and mechanical circulatory support. We are now investigating the association of adsorbed and non-adsorbed AT1R antibody to transplant outcomes. Canadian National Transplant Research Program (CNTRP). Edmonton Civic Employee’s Research Award.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,002 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,014 | 0,006 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».