Effects of Three Eye Glass Frame Designs on Relative Humidity and Temperature Measured Over the Cornea
Notice bibliographique
Résumé
Abstract
 Objective: To evaluate the relative humidity and temperature over the cornea in three different eye glass frame designs to see if frame design can influence relative humidity and temperature measured over the eyeball surface.
 Setting: Ophthalmology practice in the Denver, Colorado area
 Design: Prospective study
 Materials and Methods: Relative humidity and temperature were measured in 59 subjects in a clinical setting, with three different eye glass frame designs from June 2016 to September 2016. Measurements were made with small sensors mounted inside the eye glass lenses, to see if eyeglass frame design could influence these measured values. Baseline measures were taken with glasses off and follow-up measures with glasses on.
 Results: Relative humidity increased most markedly with a tight wraparound frame design (38.9%), followed by a smaller increase with post cataract wraparound sunglass frames (2.8%), and a minimal decrease with normal frames (-1.3 %). The temperature increased over the eyeball in all frame designs, but changed most dramatically in the tight wraparound frame (11.2 degrees).
 Conclusion: Tight wraparound eyeglass frames significantly increase the relative humidity over the cornea, as measured in this study. This frame design may offer another method of treatment for dry eye disease that is lower in cost than present therapies.
 Key Words: Dry Eye Disease, Relative Humidity.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».