A Device for Improving Oxygenation in Patients With Acute Respiratory Distress Syndrome
Notice bibliographique
Résumé
In this paper we present a device for improving blood oxygenation in patients with Acute Respiratory Distress Syndrome (ARDS). ARDS is caused by lung-related illness or injury, and can occur in mechanically ventilated ICU patients due to volutrauma or barotrauma. In ARDS, the lower lung is closed resulting in impaired gas exchange, and the upper lung is easily overstretched resulting in injury. The application of continuous negative abdominal pressure (CNAP) assists in opening the lower lung by pulling the diaphragm towards the abdomen. The device, consisting of a rigid arch, a compliant patient interface, and a pressure sensor module, allows for the application of CNAP to a patient suffering from ARDS. An initial pig trial using the prototype device showed significant improvement in the ratio of oxygen in the blood to the fraction of inspired oxygen, PaO2/FiO2, after five minutes of −5 cmH2O pressure application. Furthermore, preliminary testing on healthy humans indicated the device was comfortable, easy to apply, and formed a consistent airtight seal. Future prototypes will focus on ease of application, rigidity, and adjustability.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».