How to enhance the energy efficiency of HVAC systems
Notice bibliographique
Résumé
HVAC systems for controlled microclimate environments can be very energy consuming depending on the specific thermo-hygrometric conditions to be attained with respect to the conditions of external air.The aim of the present work is the analysis of some useful strategies devoted to reduce HVAC energy consumption.To this end, an in-house developed software is employed to evaluate energy consumption in terms of heating/cooling, humidification/dehumidification and reheat contributions.The test-case considered in this work is a museum environment where specific conditions are required to ensure long-term safety and preservation of the exhibitions by considering also visitors occupancy.The HVAC system is coupled with the exhibition room where the energy demand is computed through the microclimate energy balance.The simulation model has been validated by comparing the results in terms of energy demand to those obtained in the literature.Different strategies have been implemented to reduce the energy cost, i.e. a partial by-pass of cooling coil, an increase of the accepted tolerance for the relative humidity set-point value, an improvement of the thermal insulation of the building and a recirculation of the microclimate air.The results obtained by adopting such strategies have been compared to assess the efficiency of HVAC systems.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».