MétaCan
Menu
Retour à la cohorte
Enregistrement W2901081366 · doi:10.2196/11201

Applying Multivariate Segmentation Methods to Human Activity Recognition From Wearable Sensors’ Data

2018· article· en· W2901081366 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

venuePublié dans une revue dont le pays d'attache est le Canada.
no affAucune affiliation canadienne : ce travail est invisible pour une base fondée sur la seule affiliation.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Notice bibliographique

RevueJMIR mhealth and uhealth · 2018
Typearticle
Langueen
DomaineComputer Science
ThématiqueContext-Aware Activity Recognition Systems
Établissements canadiensnon disponible
Organismes subventionnairesNational Institute of Biomedical Imaging and BioengineeringNational Institute of Environmental Health Sciences
Mots-clésWearable computerComputer scienceMultivariate statisticsArtificial intelligenceSegmentationPattern recognition (psychology)Computer visionMachine learning

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Time-resolved quantification of physical activity can contribute to both personalized medicine and epidemiological research studies, for example, managing and identifying triggers of asthma exacerbations. A growing number of reportedly accurate machine learning algorithms for human activity recognition (HAR) have been developed using data from wearable devices (eg, smartwatch and smartphone). However, many HAR algorithms depend on fixed-size sampling windows that may poorly adapt to real-world conditions in which activity bouts are of unequal duration. A small sliding window can produce noisy predictions under stable conditions, whereas a large sliding window may miss brief bursts of intense activity. OBJECTIVE: We aimed to create an HAR framework adapted to variable duration activity bouts by (1) detecting the change points of activity bouts in a multivariate time series and (2) predicting activity for each homogeneous window defined by these change points. METHODS: We applied standard fixed-width sliding windows (4-6 different sizes) or greedy Gaussian segmentation (GGS) to identify break points in filtered triaxial accelerometer and gyroscope data. After standard feature engineering, we applied an Xgboost model to predict physical activity within each window and then converted windowed predictions to instantaneous predictions to facilitate comparison across segmentation methods. We applied these methods in 2 datasets: the human activity recognition using smartphones (HARuS) dataset where a total of 30 adults performed activities of approximately equal duration (approximately 20 seconds each) while wearing a waist-worn smartphone, and the Biomedical REAl-Time Health Evaluation for Pediatric Asthma (BREATHE) dataset where a total of 14 children performed 6 activities for approximately 10 min each while wearing a smartwatch. To mimic a real-world scenario, we generated artificial unequal activity bout durations in the BREATHE data by randomly subdividing each activity bout into 10 segments and randomly concatenating the 60 activity bouts. Each dataset was divided into ~90% training and ~10% holdout testing. RESULTS: In the HARuS data, GGS produced the least noisy predictions of 6 physical activities and had the second highest accuracy rate of 91.06% (the highest accuracy rate was 91.79% for the sliding window of size 0.8 second). In the BREATHE data, GGS again produced the least noisy predictions and had the highest accuracy rate of 79.4% of predictions for 6 physical activities. CONCLUSIONS: In a scenario with variable duration activity bouts, GGS multivariate segmentation produced smart-sized windows with more stable predictions and a higher accuracy rate than traditional fixed-size sliding window approaches. Overall, accuracy was good in both datasets but, as expected, it was slightly lower in the more real-world study using wrist-worn smartwatches in children (BREATHE) than in the more tightly controlled study using waist-worn smartphones in adults (HARuS). We implemented GGS in an offline setting, but it could be adapted for real-time prediction with streaming data.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Autre devis · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,979
Score d'incertitude au seuil0,998

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0010,000
Communication savante0,0000,001
Science ouverte0,0010,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,258
Tête enseignante GPT0,475
Écart entre enseignants0,217 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle