Wildfire Trips De-Energized Line Shunt Reactor
Notice bibliographique
Résumé
Dense smoke from wildfires within a 500-kV line corridor led to several line protection trips over a three-day period. A switchable line-connected reactor, provided to control Ferranti voltages, tripped and locked out twice by its protection shortly after the line was de-energized. Lockout operation prevented quick reactor reinsertion and impeded operational flexibility until visual inspections of the reactor were conducted on both occasions. Forensic investigation of the event concluded that the smoke increased the line capacitances. This created a near 60-Hz zero sequence resonant circuit when the line tripped and became de-energized along with the reactor. The resonant circuit amplified the capacitively coupled zero sequence 60-Hz voltage induced from circuits which run adjacent to the line for a short distance. The voltage amplification drove enough current through the reactor to trip the sensitive ground overcurrent protection. A holistic mitigation is designed to avoid reoccurrence of the incident and improve overall line reliability. The intent of this paper is to share lessons learned from the event investigation with peer utilities because this problem of unexpected operation of line shunt reactor protection has not previously been reported.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».