The direct and accurate determination of major elements Ca, K, Mg and Na in water by HR-ICPMS
Notice bibliographique
Résumé
Abstract A direct, accurate and precise method is reported for major elements Ca, K, Mg and Na measurements in river and drinking water using a high resolution ICP-MS. Double isotope dilution calibration was used for the determination of Mg whereas the combined standard addition and internal standardization (Sc) was used for Ca, K and Na measurements. The method is validated by analysis fresh water SLRS-5, SLRS-6 and SRM1640a with satisfactory results characterized by high precisions of 0.055% to 0.66% RSD (or 0.29–1.8% relative combined uncertainty) for all four analytes, superior to those reported in earlier studies. As noted, use of internal standard Sc has significantly (3–33 times) improved measurement precisions for Ca, K and Na compared to standard addition calibration alone. The proposed method was applied for the determination of major elements Ca, K, Mg and Na in a candidate drinking water CRM AQUA-1. Values of 1.908 ± 0.007 µg g −1 , 8.27 ± 0.14 µg g −1 , 0.660 ± 0.010 µg g −1 and 13.76 ± 0.05 µg g −1 ( u , k = 1) were obtained for Mg, Ca, K and Na in AQUA-1 drinking water, respectively.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».