Bluetooth Low Energy Based Activity Tracking of Patient
Notice bibliographique
Résumé
With growing demand for health care, medical clinicians and researchers need to gather quality patient centric data in order to better develop tools to improve quality of life. As an example, it has been a challenge to accurately evaluate postoperative mobility in patient care units. This paper describes the development and implementation of a proof-of-concept, a low cost and easily deployable Bluetooth Low Energy (BLE) based localization system used to identify and locate patients. Using the received signal strength (RSS) of BLE signal and the uniqueness of BLE hardware addresses, patients can be identified and located within the hospital room. The value of RSS of BLE signal from wearable BLE beacon varies with distance to the wall anchored BLE scanner. The first part of the paper presents the results of the experiments conducted in a low noise and non-reflective environment. The second half of the paper talks about the proposed algorithm of localization of the subject within the experimental room. The paper evaluates the effects of the number of BLE wall anchored scanners and the number of packets on the accuracy of the proposed algorithm. The proposed algorithm was evaluated to have better performance than other classical approaches.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».