Semi-Adaptive Closed-Loop Control for Infusion of Medications With Transport Delay in Clinical Effects
Notice bibliographique
Résumé
Abstract This paper presents a semi-adaptive closed-loop control approach to autonomous infusion of medications exhibiting significant transport delay in clinical effects. The basic idea of the approach is to enable stable adaptive control of medication infusion by (1) incorporating transport delay explicitly into control design by way of a Padé approximation while (2) facilitating linear parameterization of control design model by desensitization of nonlinearly parameterized cooperativity constant associated with pharmacodynamics (PD). A novel dynamic dose–response model for control design is presented, in which the cooperativity constant exerts zero influence on the model output in the steady-state. Then, an adaptive pole placement control (APPC) technique was employed to fulfill adaptive control design in the presence of nonminimum phase dynamics associated with the Padé approximation of transport delay. The controller was evaluated in silico using a case study of regulating a cardiovascular variable with a sedative under a wide range of transport delay and pharmacological profiles. The results suggest that adaptation of transport delay and pharmacological characteristics may be beneficial in achieving consistent and robust regulation of medication-elicited clinical effects.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».