MétaCan
Menu
Retour à la cohorte
Enregistrement W2913530646 · doi:10.1096/fasebj.2018.32.1_supplement.635.7

X‐Reality and the Microsoft HoloLens: A Hollow Tool for Anatomical Education

2018· article· en· W2913530646 sur OpenAlexaff
Liliana Wolak, Giancarlo Pukas, Josh Mitchell, Jason Lamb, Michael Romaniuk, Geoffery Norman, Sandra Monteiro, Bruce Wainman

Notice bibliographique

RevueThe FASEB Journal · 2018
Typearticle
Langueen
DomaineEngineering
ThématiqueAnatomy and Medical Technology
Établissements canadiensImpactMcMaster University
Organismes subventionnairesnon disponible
Mots-clésContext (archaeology)Augmented realityMixed realityVirtual realityComputer scienceHuman–computer interactionPelvisStereoscopyProjection (relational algebra)DisadvantageMedical physicsMedicineMedical educationArtificial intelligenceAnatomy

Résumé

récupéré en direct d'OpenAlex

Recent technological advancements in X‐Reality (XR) seem to create remarkably realistic models for anatomical education. Despite a lack of evidence regarding the efficacy of XR in this context, several institutions have adopted these technologies as primary educational tools in anatomy as an alternative to traditional cadaveric laboratories. In our earliest study, we evaluated a 3D, interactive projection on a 2D screen against a physical model of a female pelvis. This data demonstrated that those who learnt on the physical model performed significantly better during testing. Subsequently, we explored the efficacy of more intricate XR systems. Thus, we compared the efficacy of the Microsoft HoloLens, a mixed‐reality (MR) device, to a physical model in anatomy education. We recruited 20 McMaster University students and ran a preliminary study to gather qualitative data regarding the optimal MR environment. We gathered participant preference based on their experience observing several virtual objects against different coloured backgrounds and various lighting combinations. We used this data to build the testing environment for the MR model, such as adding black curtains and floor tiles to the room, and using a single light over the projection. These conditions were also used for the physical model, thus placing it at a slight disadvantage. We then recruited 40 McMaster University students with no prior anatomical education, and randomized them into two groups: one learning on a physical model of a female pelvis and one learning on the MR model of a female pelvis. We measured two possible covariates, spatial and stereoscopic ability, through two pretest assessments: a Mental Rotations Test (MRT) and a Titmus Fly Test, respectively. Our participants were then given 10 minutes to learn 20 structures using their respective models, and were tested on a female cadaveric pelvis on the basis of a 25‐question test with no time limit. This test included 15 nominal questions, which asked participants to name the indicated structure, and 10 functional questions, which asked participants to determine the function of a structure based on its location and form. We hypothesized that due to the realistic model that the MR system created, it should perform at least equivalent to the physical model in the context of anatomical education. Our assessments found that participants learning on the physical model performed significantly better in comparison to their MR counterparts on both nominal (65% vs 41%, respectively; p = 0.0051) and functional measures (42% vs. 31%, respectively; p = 0.0134). Additionally, when controlling for the aforementioned covariates, we found these results to remain consistent. Ultimately, our results indicate that the MR device is an inefficient tool for anatomical education when compared to traditional physical models. Our future directions involve exploring possible determinants influencing the superiority of the physical model, such as stereoscopic vision, as well as the assessment of other XR systems, such as virtual reality headsets, in the context of anatomy education. Support or Funding Information Self‐funded. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Autre devis · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,798
Score d'incertitude au seuil0,175

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,010
Tête enseignante GPT0,255
Écart entre enseignants0,245 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeAutre devis
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2018
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueThe FASEB JournalMême sujetAnatomy and Medical TechnologyTravaux en français237 207