MétaCan
Menu
Retour à la cohorte
Enregistrement W2914892732 · doi:10.1149/ma2018-02/13/656

The Effect of Hydrogen Absorption on the Passivity of Oxides on Carbon Steels

2018· article· en· W2914892732 sur OpenAlexaff
Maxwell Goldman, Claire Trully, Dmitrij Zagidulin, Jamie Noel, D.W. Shoesmith

Notice bibliographique

RevueECS Meeting Abstracts · 2018
Typearticle
Langueen
DomaineMaterials Science
ThématiqueMaterial Properties and Failure Mechanisms
Établissements canadiensWestern University
Organismes subventionnairesnon disponible
Mots-clésCorrosionMaterials scienceOxideHydrogen embrittlementStress corrosion crackingHydrogenX-ray photoelectron spectroscopyPolarization (electrochemistry)MetallurgyChemical engineeringAnalytical Chemistry (journal)Chemistry

Résumé

récupéré en direct d'OpenAlex

Pipelines are designed for a wide variety of applications. Their use in the energy sector for the transportation of crude oil, natural gas, and other petrochemical commodities is still regarded as the safest, fastest and most economical mode of product transmission and delivery. The degradation of the structural integrity of pipelines caused by corrosion has been an on-going problem. Depending on in-service use, different forms of corrosion can occur, with the deleterious effects depending on which type of corrosion is occurring, such as stress corrosion cracking (SCC) and hydrogen induced cracking (HIC) due to hydrogen embrittlement (HE). Further, the hydrogen may affect the protectiveness of any Fe III oxide present on the steel surface. This study investigates the effects of H absorption by X60, X65, X70 steels. A range of electrochemical techniques, such as monitoring the corrosion potential (E corr ), polarization resistance (R p ) measurements, cyclic voltammetry (CV), and H permeation experiments (using the Devanathan-Stachurski (D-S) approach) have been used to investigate the effect of H on the steel and the oxides present on the steel surface. Surface analytical techniques such as X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS) were used to determine the effect of H on the composition of the oxide and to identify the distribution of H trapping sites. The apparent diffusivity of H in X65 was found to depend on the composition of the solution on the reduction side of the D-S cell. The steady-state current measured in the oxidation cell was dependent on the solution composition in the reduction cell. The presence of calcium caused a sharp decrease of oxidation current, likely due to the quick formation of calcium carbonate deposits, whereas magnesium caused a gradual decrease in the observed oxidation current, which is likely due to the thickening of the magnesium hydroxide on the surface. The presence of both calcium and magnesium in the solution affects the amount of H that diffuses through the steel, likely by blocking adsorption sites on the steel surface. Blocked adsorption sites reduce the concentration of atomic hydrogen on the surface and lead to a decrease in the observed steady-state current. Thermal desorption data show that, in the X65 steel, a majority of the H trapped within the steel requires activation energy (E a ) of < 50 kJ/mol for its release, indicating that it is located in reversible trapping sites. SIMS data suggest that trapping occurs predominantly along grain boundaries, with the extent of H trapping at these sites possibly affecting the resistance of the surface Fe III oxides present. The R P values measured after cathodic charging for the pearlite-containing steel (X65) were lower than those obtained on the bainite-containing steel (X70). The presence of FeO on the steel surface after cathodic charging suggests partial oxide reduction, with this reduced oxide being more prominent on the X65 than on the X70 steel. Polarization resistance measurements were used to study the role of hydrogen on the passivity of the steel covered by iron oxides. It has been shown that at open circuit conditions the increase in R P value is slower when the steel has been charged with H. The phase of X70 being investigated was predominantly bainite, which is more resistive to hydrogen absorption. X70, after hydrogen charging, was found to have a lesser change in steady-state R P than did the X65. Further, the retardation of the resistance increase at open circuit was more prominent on the X65 than on the X70. XPS confirmed that more FeO was present on the X65 sample after charging than on the X65 after charging followed by potentiodynamic polarization experiments. All this suggests that, at open circuit conditions after the steel was charged with H, hydrogen being released from reversible trapping sites reduces the Fe III oxide to FeO. The reduction of Fe III to FeO, due to either the charging or release of atomic hydrogen trapped within the lattice, is likely causing a decrease in the resistance of the passive oxide.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,003
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,025
Score d'incertitude au seuil0,256

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0030,001
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,013
Tête enseignante GPT0,224
Écart entre enseignants0,211 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2018
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueECS Meeting AbstractsMême sujetMaterial Properties and Failure MechanismsTravaux en français237 207