Benefit of Watching a Live Visual Inspection of the Cervix With Acetic Acid and Lugol Iodine on Women’s Anxiety: Randomized Controlled Trial of an Educational Intervention Conducted in a Low-Resource Setting
Notice bibliographique
Résumé
BACKGROUND: Women undergoing pelvic examination for cervical cancer screening can experience periprocedural anxiety. OBJECTIVE: The aim of this study was to assess the anxiety level experienced by women undergoing a visual inspection with acetic acid and Lugol iodine (VIA and VILI) examination, with or without watching the procedure on a digital screen. METHODS: This prospective randomized study took place in the district of Dschang, Cameroon. A previous cervical cancer screening campaign tested women aged between 30 and 49 years for human papillomavirus (HPV). HPV-positive women were invited for the 12-month follow-up control visit, including a VIA/VILI examination. During that visit, we recruited women to participate in this study. Before the examination, participants were randomized in a 1:1 ratio to a control group (CG) and an intervention group (IG). Women in both groups underwent a pelvic examination and were verbally informed about the steps undertaken during the gynecological examination. The IG could also watch it live on a tablet screen. Women's anxiety was assessed before and immediately after the examination, using the Spielberger State-Trait Anxiety Inventory (STAI). A paired t test was used to compare the mean STAI score for each question before and after VIA/VILI while a nonpaired, 2-sided t test was used to compare the mean differences of the STAI score between the 2 study groups. RESULTS: A total of 122 women were randomized in the study; 4 of them were excluded as they did not undergo the pelvic examination, did not answer to the second STAI questionnaire because of personal reasons, or the cervix could not be properly visualized. Thus, the final sample size consisted of 118 patients of whom 58 women were assigned to the CG and 60 to the IG. The mean age was 39.1 (SD 5.2) years. Before the examination, the mean (SD) STAI score was 33.6 (SD 10.9) in the CG and 36.4 (SD 11.8) in the IG (P=.17). The STAI score after pelvic examination was significantly reduced for both groups (CG: 29.3 [SD 11.2]; IG: 28.5 [SD 12.0]). Overall, the difference of the STAI scores before and after the pelvic examination was lower in the CG (4.2 [SD 9.0]) than in the IG (7.9 [SD 14.3]), although the difference was not significant (P=.10). However, the women's emotional state, such as I feel secure and I feel strained, was improved in the IG as compared with the CG (CG: P=.01; IG: P=.007). CONCLUSIONS: Watching the VIA/VILI procedure in real time improved the women's emotional state but did not reduce the periprocedural anxiety measured by the STAI score. Furthermore, larger studies should assess women's satisfaction with watching their pelvic examination in real time to determine whether this tool could be included in VIA/VILI routine practice. TRIAL REGISTRATION: ClinicalTrials.gov NCT02945111; http://clinicaltrials.gov/ct2/show/NCT02945111.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,004 | 0,002 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,003 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,012 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».