Determination of fasiglifam-induced liver toxicity: Insights from the data monitoring committee of the fasiglifam clinical trials program
Notice bibliographique
Résumé
BACKGROUND: Different approaches to safety event collection influence the determination of liver toxicity within drug development programs. Herein, a description of how fasiglifam-induced liver injury was detected is provided. METHODS: This eight-trial drug development program was intended to evaluate fasiglifam (25 mg, 50 mg) against placebo or active comparators (glimepiride, sitagliptin) in approximately 11,000 suboptimally controlled patients with type 2 diabetes (terminated Dec 2013 due to liver toxicity). Liver safety had been pre-identified as a concern, and within the phase 3 trials, was measured through (1) adverse event reporting, (2) central predefined liver monitoring schedule with various thresholds for potential drug-induced liver injury, and (3) blinded adjudication of serious liver toxicity by a panel of experts in drug-induced liver injury. A single data monitoring committee provided safety oversight across all trials within the program. FINDINGS: Prior to program termination, 7595 of 7602 (99.9%) randomized participants across the eight trials received at least one dose of the study drug (fasiglifam, placebo, or active control). No concerning trends were noted in adverse or serious adverse event frequency, suspected unexpected serious adverse reaction, alanine or aspartate transaminase elevations, or hepatobiliary or gastrointestinal adverse events as reported by local site investigators. However, the predefined central liver safety measurements revealed a greater frequency of possible Hy's Law cases (5 vs 2) and a 3- to 7-fold greater relative risk in alanine or aspartate transaminase elevation (with respect to upper limit of normal) within fasiglifam recipients compared with placebo/active control: alanine or aspartate transaminase > 3×: relative risk 3.34 (95% confidence interval 2.29-4.90), alanine or aspartate transaminase > 5×: relative risk 6.60 (95% confidence interval 3.03-14.38), alanine or aspartate transaminase > 8×: relative risk 6.14 (95% confidence interval 2.18-17.27), and alanine or aspartate transaminase > 10×: relative risk 6.74 (95% confidence interval 2.05, 22.14). All elevations resolved on study drug discontinuation. Drug-induced liver injury was adjudicated as highly likely or probably related in 0.64% of fasiglifam-treated versus 0.06% placebo or active control-treated patients. CONCLUSION: In spite of clear liver toxicity detected with a systematic surveillance program, liver safety signals were not identified from investigator adverse event reporting alone. By integrating key safety monitoring processes within the randomized design of adequately sized clinical trials, the rare but serious liver toxicity signal became clear, leading to timely program termination.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,076 | 0,066 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,003 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».