6.8 A 36Gb/s Adaptive Baud-Rate CDR with CTLE and 1-Tap DFE in 28nm CMOS
Notice bibliographique
Résumé
Baud-rate clock-and-data recovery circuits (CDR) are ubiquitous in recent receiver designs as a means of lowering power consumption by sampling the data only once per UI. To further reduce power, prior works in pattern-based baud-rate PD [1] and FD [2] combine clock & data recovery by sharing comparators between the DFE and the PD. However, both CDRs [1, 2] were manually tuned by sweeping the equalization settings of the CTLE and the comparator levels in order to achieve lock. Since the two settings are correlated, it is time-consuming and tedious to sweep the entire solution space. In this paper, we propose an adaptive engine where the CDR system searches and converges to an optimal lock and sampling point. The proposed scheme, implemented in 28nm CMOS and operating at 36Gb/s, relies on the data eye to autonomously adapt the parameters of a CTLE, a 1-tap DFE, and the PD locking point.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».