Small-Volume Tubes to Reduce Transufusion (STRATUS): A Pilot Study

2018· article· en· W2922010758 sur OpenAlexaffabout
Tara Pinto, Emilie P. Belley‐Côté, Aliya Esmail, Elena Zotova, Brandi Meeks, Stuart J. Connolly, Deborah Siegal

Notice bibliographique

RevueBlood · 2018
Typearticle
Langueen
DomaineMedicine
ThématiqueBlood transfusion and management
Établissements canadiensMcMaster UniversityPopulation Health Research Institute
Organismes subventionnairesnon disponible
Mots-clésMedicineVacutainerBlood volumeIntensive care unitBlood transfusionHematocritAnemiaSurgeryEmergency medicineIntensive care medicineAnesthesiaInternal medicine

Résumé

récupéré en direct d'OpenAlex

Abstract Background: Blood sampling for diagnostic testing can result in significant blood loss, particularly in critically ill patients who undergo frequent testing and in whom anemia and red blood cell (RBC) transfusion are frequent. Only 10% of blood collected is used for testing procedures suggesting that small-volume tubes may reduce the incidence/severity of anemia and RBC transfusion without compromising care. Small-volume Vacutainer® tubes for blood collection (2-3 mL) have the same cost, physical dimensions, and blood draw techniques as standard-draw tubes (4-10 mL), and are compatible with laboratory equipment. Our objective was to evaluate the feasibility of a pragmatic randomized trial to determine whether a policy of small-volume tubes reduces RBC transfusion compared to standard tubes in adult intensive care unit (ICU) patients. Methods: We performed a mixed-methods prospective pilot study (before-after design) in the cardiovascular ICU in Hamilton, Canada. The study consisted of a 6-week control period (current practice of standard-volume tubes) and a 6-week intervention period (small-volume tubes) separated by a 2-week washout period. All patients admitted to the ICU were included and followed for 30 days, or until discharge or death. The primary outcome was feasibility as follows: (i) successful switch to small-volume tubes; (ii) adherence to correct tube size; (iii) sufficient volume for testing (less than 3% inadequate); (iv) user acceptance (nurses, lab techs, etc.); (v) assessment of barriers and facilitators to implementation; and (vi) 95% complete primary data collection. Secondary outcomes were reduction in blood loss with small-volume tubes, change in hemoglobin (Hb) level from ICU admission to discharge (adjusted for RBC transfusion), RBC transfusion, ICU/hospital mortality and ICU/hospital length of stay. End-user acceptability and barriers/facilitators to implementation were explored using focus group discussions (FGD). Thematic analysis from FGDs was conducted using NVivo software (QSR International). Results: From December 1 to February 6, 2018, 369 patients were included in the study, 165 in the control and 204 in the intervention periods. The median (IQR) age was 70 yrs (61 - 76) in the control group and 67 yrs (59 - 74) in the intervention group. The median (IQR) ICU stay was 1 day (1-35) for both groups. Random audits demonstrated 100% compliance with allocated tube size. Median (IQR) estimated blood loss due to laboratory testing per patient per day in ICU was 11 mL (8-17) in the control period and 6 mL (4-8) mL intervention period, corresponding to a 45% reduction in blood loss. Total median (IQR) estimated blood loss was 24 mL (16-58) and 15 mL (11-26), in the control and intervention periods, respectively. The median (IQR) adjusted Hb at discharge was 62 g/L (43 - 70) in the control period and 63 g/L (56 - 70) in the intervention period. The proportion of samples with inadequate volume for testing was similar for both groups (0.2% vs. 0.2%, p= 0.72). RBC transfusions were administered to 46 patients (28%) in the control group and 41 (20%) patients in the intervention group (p=0.084). The median (IQR) number of transfusions in the control and intervention periods was 2 units (1-4) and 2 units (1-2) units, respectively. There were 9 deaths (5.5%) in the control group and 3 deaths (1.5%) in the intervention group (0.04). Based on 10 FGDs with 24 ICU nurses and 9 laboratory staff, small-volume tubes were acceptable with no significant barriers to implementation identified. Conclusion: In this pilot study, small-volume tubes were successfully implemented for routine laboratory testing with acceptability to end-users and without significant barriers. Use of small-volume tubes resulted in a reduction in blood loss for laboratory testing by 45% with no increased frequency of inadequate samples. Our results suggest that small-volume tubes are a feasible intervention to reduce the volume of blood taken for laboratory testing in adult ICU patients. These results will inform a full-scale stepped wedge cluster randomized trial to determine whether a policy of small-volume tubes reduces RBC transfusion in adult ICU patients. Disclosures Siegal: Portola Pharmaceuticals: Honoraria; BMS-Pfizer: Honoraria; Bayer: Honoraria.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,005
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,010
Score d'incertitude au seuil0,027

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0050,005
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0020,002
Bibliométrie0,0010,001
Études des sciences et des technologies0,0010,002
Communication savante0,0010,001
Science ouverte0,0010,001
Intégrité de la recherche0,0020,002
Charge utile insuffisante (le modèle a refusé de juger)0,0040,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,045
Tête enseignante GPT0,281
Écart entre enseignants0,236 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations2
Publié2018
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueBlood→Même sujetBlood transfusion and management→Travaux en français237 207→