Energy efficiency of a nanosecond repetitively pulsed discharge for methane reforming
Notice bibliographique
Résumé
Abstract The performance of a nanosecond repetitively pulsed discharge for CH 4 reforming is studied at atmospheric pressure for temperatures ranging from 300 to 700 K. The high-voltage pulser used is capable of producing a voltage pulse with an amplitude of 14 kV and a duration of 40 ns at a repetition frequency of 10 kHz. The discharge energy per pulse is varied in a range from 462 J to 2.47 mJ. The rotational temperature is estimated by fitting synthetic to experimental spectra. Experiments at pulsing frequency of 1 kHz led to temperature profiles that remain unchanged along the axial direction of the reactor. For pulse frequencies between 2–10 kHz, the average temperature of the filament rises from 507 to 777 K. Emission from C 2 (A –X ) is compared to emission from CH(A –X ) along the reactor axis and with respect to the energy input. It is found that as the energy input increases, so does the emission from C 2 (A –X ), turning the discharges green rather than blue. Results from CH 4 conversion show that the inlet gas temperature has negligible effect on reforming performance. Higher values of energy per pulse improve conversion and energy efficiency. However, increasing the pulse frequency leads to the best performance enhancement with a maximum slope of 0.53% and 0.24% per kJ · mol −1 for conversion and energy efficiency, respectively. The maximum conversion and energy efficiencies were 68.2% and 25.6%, respectively, measured in a CH 4 –air mixture.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».