Self-powered, flexible and remote-controlled breath monitor based on TiO <sub>2</sub> nanowire networks
Notice bibliographique
Résumé
Abstract Smart breath monitor devices with high stretchability, fast response/recovery times and self-powered characteristic are essential in the wearable medical and life science applications. In this work, we report on the development of a versatile high-performance humidity sensor based on TiO 2 nanowire networks for self-powered sensing application of human breath monitoring. These sensors, with typical response times of ∼3.6 s and recovery times of ∼14 s, exhibit high sensitivity to water vapor and can yield an output voltage that is directly proportional to the humidity level of ambient environment. The structure of nanowire networks is highly flexible and maintains the output voltage even after 10 000 times bending. By combining this type of sensor with a commercial signal transmission and processing system, it shows the good basis for real-time/remote-controlled monitoring and analysis of human breath under a variety of respiratory conditions. Our results suggest a new class of humidity sensing for self-powered biomedical devices and open to new technologies in energy, electronics, and sensor applications.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».