MétaCan
Menu
← tous les travaux

Ultrafine particles and PM2.5 in the air of cities around the world: Are they representative of each other?

2019· article· en· 189 citations· W2946687899 sur OpenAlex· 10.1016/j.envint.2019.05.021

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Affiliation canadienneUne personne signataire a déclaré un établissement canadien. C'est la seule voie dont dispose la base habituelle.

Prédiction distillée sur la base complète

Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

Catégories candidates
Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuelles
aucune
Domaine
Signal candidat: aucuneSignal consensuel: aucune
Devis d'étude
Signal candidat: ObservationnelSignal consensuel: Observationnel
Genre
Signal candidat: EmpiriqueSignal consensuel: Empirique
Score de désaccord entre enseignants
0,013
Score d'incertitude au seuil
0,999
Statut de validation
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Tête enseignante Opus0,035
Tête enseignante GPT0,307
Écart entre enseignants
0,272 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validation
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Résumé

Can mitigating only particle mass, as the existing air quality measures do, ultimately lead to reduction in ultrafine particles (UFP)? The aim of this study was to provide a broader urban perspective on the relationship between UFP, measured in terms of particle number concentration (PNC) and PM2.5 (mass concentration of particles with aerodynamic diameter < 2.5 μm) and factors that influence their concentrations. Hourly average PNC and PM2.5 were acquired from 10 cities located in North America, Europe, Asia, and Australia over a 12-month period. A pairwise comparison of the mean difference and the Kolmogorov-Smirnov test with the application of bootstrapping were performed for each city. Diurnal and seasonal trends were obtained using a generalized additive model (GAM). The particle number to mass concentration ratios and the Pearson's correlation coefficient were calculated to elucidate the nature of the relationship between these two metrics. Results show that the annual mean concentrations ranged from 8.0 × 103 to 19.5 × 103 particles·cm−3 and from 7.0 to 65.8 μg·m−3 for PNC and PM2.5, respectively, with the data distributions generally skewed to the right, and with a wider spread for PNC. PNC showed a more distinct diurnal trend compared with PM2.5, attributed to the high contributions of UFP from vehicular emissions to PNC. The variation in both PNC and PM2.5 due to seasonality is linked to the cities' geographical location and features. Clustering the cities based on annual median concentrations of both PNC and PM2.5 demonstrated that a high PNC level does not lead to a high PM2.5, and vice versa. The particle number-to-mass ratio (in units of 109 particles·μg−1) ranged from 0.14 to 2.2, >1 for roadside sites and <1 for urban background sites with lower values for more polluted cities. The Pearson's r ranged from 0.09 to 0.64 for the log-transformed data, indicating generally poor linear correlation between PNC and PM2.5. Therefore, PNC and PM2.5 measurements are not representative of each other; and regulating PM2.5 does little to reduce PNC. This highlights the need to establish regulatory approaches and control measures to address the impacts of elevated UFP concentrations, especially in urban areas, considering their potential health risks.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
Environment International
Thématique
Air Quality and Health Impacts
Domaine
Environmental Science
Établissements canadiens
Occupational Cancer Research CentreUniversity of Toronto
Organismes subventionnaires
Ministero dell’Istruzione, dell’Università e della RicercaDipartimenti di Eccellenza
Mots-clés
Aerodynamic diameterUltrafine particleAtmospheric sciencesAir quality indexEnvironmental scienceMass concentration (chemistry)Bootstrapping (finance)SeasonalityAerosolMeteorologyGeographyStatisticsMathematicsChemistryEconometricsPhysics
Résumé présent dans OpenAlex
oui