Perioperative Mortality Secondary to a Pulmonary Embolism During a Surgical Implantation of the Endo-Exo-Prosthesis: A Case Report
Notice bibliographique
Résumé
We report on a 53-year-old female patient who suffered a perioperative death secondary to a pulmonary embolism (PE) during an implantation of Endo-Exo-Prosthesis. This is a retrospective review of medical case for a patient who had a previous above-the-knee amputation secondary to a failed previous arthroplasty surgery. Our planned surgery was a stage 1 implantation of an Endo-Exo-Prosthesis, and it was performed under general anaesthesia. After 25 min from starting the surgical procedure, the patient sustained a cardiac arrest, and despite an active cardiopulmonary resuscitation for 50 min, the patient did not recover, the ventilator machine was stopped later on, and the patient was declared deceased at that stage. Fatal intraoperative PE is a rare but significant complication during orthopaedic procedures. There are few reports of similar events but include mainly trauma patients with fractured neck of femur. Endo-Exo-Prosthesis is a relatively newly evolved procedure in a unique group of patients. To our knowledge, this is the first case report of such complication during Endo-Exo-Prosthesis implantation. Patient and surgeon should be aware of it, and additional preventive measures like preoperative scoring systems and in special cases using inferior vena cava filter should be considered in patients with high risk of developing venous thromboembolism.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».