Large head ceramic-on-ceramic bearing in primary total hip arthroplasty: average 3-year follow-up of a multicentre study
Notice bibliographique
Résumé
BACKGROUND: Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. National registries have shown promising results at short-term with large diameter ceramic-on-ceramic THA, with very low revision rates.This study reports on the average 3-year follow up of a press-fit monoblock large diameter acetabular shell with a pre-assembled ceramic liner, with emphasis on the radiographic outcome, complications related to the implantation of the cup, and the patient's clinical outcome. METHODS: 170 hips in 169 patients were reviewed at an average 38 ± 5.8 months following surgery. RESULTS: The radiographic review revealed no acetabular cup loosening, no osteolysis and no cup migration. 1 acetabular cup was revised for malposition. The patient clinical outcome and the satisfaction rate were excellent. At 3 years, 7.1% of patients complained of groin pain and 3.5% spontaneously reported hip joint generated noise. 1 patient sustained a non-recurrent traumatic hip dislocation 2 years post surgery. CONCLUSIONS: New technology should be introduced cautiously on the market. This is especially true for the large diameter ceramic monoblock acetabular component used in this study since it involves a new acetabular component design. At short term, we have not identified new modes of failure with this implant. Longer follow-up is still needed to assess the safety of large ceramic bearing in THA.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».