MétaCan
Menu
Retour à la cohorte
Enregistrement W2969691081

Experimental Study on Transient Behavior of Water and Nanofluid in Multiport Slab Minichannel Heat Exchangers

2019· article· en· W2969691081 sur OpenAlexfundno aff
Shahram Fotowat

Notice bibliographique

RevueScholarship at UWindsor (University of Windsor) · 2019
Typearticle
Langueen
DomaineEngineering
ThématiqueHeat Transfer and Optimization
Établissements canadiensnon disponible
Organismes subventionnairesNatural Sciences and Engineering Research Council of CanadaUniversity of Windsor
Mots-clésNanofluidHeat exchangerSlabTransient (computer programming)MechanicsMaterials scienceThermodynamicsHeat transferEngineeringComputer sciencePhysicsStructural engineering
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

Heat exchangers are essential components of many systems and their use is extended to include various industrial, chemical, and automotive applications. A dynamic response study of a heat exchanger is essential for better representation of its design, selection, and analysis as it operates in conjunction with other process equipment. This study aims to experimentally investigate the transient performance of compact heat exchangers. A wide-range well prepared experimental setup is designed and assembled to examine the transient behavior of various types of cross-flow liquid to air heat exchangers. This set up is capable of stepping up or down the temperatures and flow rates for both hot and cold fluids covering a broad range of perturbations that occur in transient scenarios. A step function is a close approximation of a transient variation in heat exchangers, therefore, this work examines the transient response of both fluids under hot liquid side step changes in mass flow from 0.5 to 2.5, and inlet temperature from 1.5 to 3.5 while air inlet conditions are kept constant. Results are presented in terms of transient dimensional and non-dimensional outlet responses of fluids temperatures, heat transfer rates, heat balance, normalized outlet temperatures, and effectiveness. The current experimental findings provide an overview of the characteristic behavior of specific parameters such as response time, initial delay and time constant of both fluids. A comparison of the results obtained is made with the limited experimental work found in the literature. It is observed that the response time is faster for both fluids with the increase of the mass and temperature perturbations and it is higher for the hot liquid than the cold air side. An adverse trend is found between the hot and cold fluids’ effectiveness in temperature step changes, while the same trend is found in mass flow steps. Mass flow step changes for positive and negative steps exhibit an asymmetric trend of both fluids. This work also examines the transient effect of using an engineered fluid, such as Al2O3/water nanofluid, in heat exchangers due to their improved thermophysical properties. The nanofluid is analyzed in terms of its particle size distribution, chemical characterization, and agglomeration of suspensions using the Transmission electron microscopy (TEM), Energy- Dispersive Spectrometry (EDS) and Dynamic light scattering (DLS). Experimental results show that the response time of the nanofluid for the temperature and mass flow steps are faster compared to water. An increase of up to 19% in heat transfer rate is observed when using nanofluid. A comparison of the dynamic performance of a minichannel heat exchanger and a conventional radiator using step variations in inlet liquid temperature and mass flow rate is investigated. Results show longer response time for the conventional radiator compared to the minichannel heat exchanger. In addition, the analytical model for transient heat exchanger response is assessed with the non-dimensional outlet temperature response of a traditional tube and fin heat exchanger subjected to mass flow step changes. A more than 20% overestimate prediction is found for the transient temperature responses using the analytical model. The Empirical correlations developed for temperature and mass flow rate steps are found in a good agreement with the experimental data. The conclusion reached in this study provides an insight on the transient behavior of conventional and minichannel heat exchangers under liquid mass flow and temperatures steps. This experimental work is used to further establish and enrich a database for future advances on the dynamic response of heat exchangers subjected to step changes in liquid inlet conditions.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,288
Score d'incertitude au seuil0,844

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,017
Tête enseignante GPT0,215
Écart entre enseignants0,198 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2019
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueScholarship at UWindsor (University of Windsor)Même sujetHeat Transfer and OptimizationTravaux en français237 207