MétaCan
Menu
Retour à la cohorte
Enregistrement W2972321633 · doi:10.1103/physrevd.100.052004

Improved measurement of the reactor antineutrino flux at Daya Bay

2019· article· en· W2972321633 sur OpenAlexaff
D. Adey, Fengpeng An, A. B. Balantekin, H. R. Band, M. Bishai, S. Blyth, D. Cao, G. F. Cao, Jun Cao, Y. L. Chan, J. F. Chang, Y. Chang, H.S. Chen, S. M. Chen, Y. Chen, Y. X. Chen, Jie Cheng, Zhaokan Cheng, J. J. Cherwinka, M. C. Chu, A. Chukanov, J. P. Cummings, F. S. Deng, Ying Ding, M. Diwan, M. Dolgareva, J. Dove, D. A. Dwyer, W. R. Edwards, M. Gonchar, G. H. Gong, Haipeng Gong, W. Gu, Lei Guo, X. H. Guo, Yuhang Guo, Ziwei Guo, R. Hackenburg, S. Hans, M. He, K. M. Heeger, Y. K. Heng, A. Higuera, Y. Hsiung, Beibei Hu, T. Hu, Z. Hu, H. X. Huang, X. T. Huang, Y. B. Huang, Patrick Huber, W. Huo, Ghulam Hussain, D. E. Jaffe, K. L. Jen, X. L. Ji, Xingzhao Ji, R. A. Johnson, D. Jones, Li-Wei Kang, S. H. Kettell, L. W. Koerner, S. Kohn, M. Krämer, T. J. Langford, L. Lebanowski, J. Lee, J. H. C. Lee, R. T. Lei, R. Leitner, J. K. C. Leung, C. Li, F. Li, H. L. Li, Q. J. Li, S. Li, S. J. Li, W. D. Li, X. N. Li, X. Q. Li, Yufeng Li, Z. B. Li, Han Liang, C.-J. Lin, Guey-Lin Lin, S. Lin, Y. C. Lin, J. J. Ling, J. M. Link, L. Littenberg, B. R. Littlejohn, J. C. Liu, J. L. Liu, Y. Liu, Y. H. Liu, T. Lohse, Cai-Dian Lü, H. Q. Lu, J. S. Lu, K. B. Luk, X. B., X. Y., Y. Q., Yury Malyshkin, C. Marshall, D. A. Martínez Caicedo, Kirk T. McDonald, R. D. McKeown, I. V. Mitchell, L. Mora Lepin, J. Napolitano, D. Naumov, E. Naumova, J. P. Ochoa‐Ricoux, A. Olshevskiy, H.-R. Pan, J. Park, S. Patton, V. Pec, J. C. Peng, L. Pinsky, C. S. J. Pun, F. Z. Qi, M. Qi, X. Qian, Rui Qiu, N. Raper, Jie Ren, R. Rosero, B. Roskovec, X. C. Ruan, H. Steiner, J. L. Sun, Konstantin Treskov, W.-H. Tse, C. E. Tull, B. Viren, V. Vorobel, C. H. Wang, Jun Wang, M. Wang, N. Y. Wang, R. G. Wang, Xiang-Gao Wang, Y. F. Wang, Zheng Wang, Zhimin Wang, Zhe Wang, H. Wei, L. H. Wei, Liangjian Wen, K. Whisnant, C. G. White, T. Wise, H. L. H. Wong, S. C. F. Wong, E. Worcester, Qian Wu, W. Wu, D. M. Xia, Z. Z. Xing, Jinliang Xu, T. Xue, C. G. Yang, Heng Yang, L. Yang, M. Yang, M. T. Yang, Y. Z. Yang, M. Ye, M. Yeh, B. L. Young, H. Z. Yu, Zeyuan Yu, B. B. Yue, S. Zeng, Liang Zhan, C. Zhang, C. C. Zhang, Feifan Zhang, H. H. Zhang, J. W. Zhang, Qingmin Zhang, R. Zhang, X. F. Zhang, X. T. Zhang, Y. M. Zhang, Y. M. Zhang, Y. X. Zhang, Y. Y. Zhang, Z. J. Zhang, Zongzhen Zhang, Z. Y. Zhang, J. Y. Zhao, Peng Zheng, L. Zhou, H. L. Zhuang, J. H. Zou

Notice bibliographique

RevuePhysical review. D/Physical review. D. · 2019
Typearticle
Langueen
DomainePhysics and Astronomy
ThématiqueNeutrino Physics Research
Établissements canadiensInstitute of Particle Physics
Organismes subventionnairesCAS Center for Excellence in Particle PhysicsResearch Grants Council, University Grants CommitteeChinese Academy of SciencesRussian Foundation for Basic ResearchGovernment of Guangdong ProvinceNational Natural Science Foundation of ChinaChina RailwayUniverzita Karlova v PrazeU.S. Department of EnergyNational Science Foundation
Mots-clésFissionDelayed neutronNuclear physicsFlux (metallurgy)PhysicsCalibrationNeutronYield (engineering)Neutron emissionNeutron fluxIsotopeFission product yieldFission productsMaterials science

Résumé

récupéré en direct d'OpenAlex

This work reports a precise measurement of the reactor antineutrino flux using 2.2 million inverse beta decay (IBD) events collected with the Daya Bay near detectors in 1230 days. The dominant uncertainty on the neutron detection efficiency is reduced by 56% with respect to the previous measurement through a comprehensive neutron calibration and detailed data and simulation analysis. The new average IBD yield is determined to be $(5.91\ifmmode\pm\else\textpm\fi{}0.09)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}43}\text{ }\text{ }{\mathrm{cm}}^{2}/\text{fission}$ with total uncertainty improved by 29%. The corresponding mean fission fractions from the four main fission isotopes $^{235}\mathrm{U}$, $^{238}\mathrm{U}$, $^{239}\mathrm{Pu}$, and $^{241}\mathrm{Pu}$ are 0.564, 0.076, 0.304, and 0.056, respectively. The ratio of measured to predicted antineutrino yield is found to be $0.952\ifmmode\pm\else\textpm\fi{}0.014\ifmmode\pm\else\textpm\fi{}0.023$ ($1.001\ifmmode\pm\else\textpm\fi{}0.015\ifmmode\pm\else\textpm\fi{}0.027$) for the Huber-Mueller (ILL-Vogel) model, where the first and second uncertainty are experimental and theoretical model uncertainty, respectively. This measurement confirms the discrepancy between the world average of reactor antineutrino flux and the Huber-Mueller model.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Charge utile insuffisante (le modèle a refusé de juger)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,099
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0020,002
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0020,001
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,002

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,025
Tête enseignante GPT0,402
Écart entre enseignants0,377 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations45
Publié2019
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuePhysical review. D/Physical review. D.Même sujetNeutrino Physics ResearchTravaux en français237 207