MétaCan
Menu
Retour à la cohorte
Enregistrement W2974525811 · doi:10.1116/1.5121197

Dark current–voltage characteristics of vacuum deposited multilayer amorphous selenium-alloy detectors and the effect of x-ray irradiation

2019· article· en· W2974525811 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.
fundUn bailleur canadien est enregistré sur le travail.

Notice bibliographique

RevueJournal of Vacuum Science & Technology A Vacuum Surfaces and Films · 2019
Typearticle
Langueen
DomaineEngineering
ThématiqueAdvanced Semiconductor Detectors and Materials
Établissements canadiensCégep de Saint-LaurentUniversity of Saskatchewan
Organismes subventionnairesNatural Sciences and Engineering Research Council of Canada
Mots-clésDark currentMaterials scienceX-ray detectorSubstrate (aquarium)VoltageBiasingOptoelectronicsElectrodeDetectorAmorphous solidOpticsCurrent (fluid)Analytical Chemistry (journal)PhysicsPhotodetectorChemistry

Résumé

récupéré en direct d'OpenAlex

Doped and stabilized amorphous selenium (a-Se) alloys in a multilayer form are currently used as a photoconductor in direct conversion flat panel x-ray imagers in mammography and tomosynthesis. While much progress has been made on the physics of such detectors, there are still unresolved questions on such issues as the principles of operation of the so-called p-i-n detector structure in extinguishing the dark current. The present paper examines dark current transients after the application of a voltage in seven types of a-Se alloy based devices: i-layer, i-n, n-i, i-p, p-i, p-i-n, and n-i-p structures. The substrate was ITO coated glass, the top (radiation receiving) electrode was chromium, and the films were fabricated by vacuum deposition. The nominal device thickness was 200 μm, similar to commercial mammographic detectors. It is shown that n-i, i-n, n-i-p, and p-i-n devices have dark currents less than 1 pA mm−2 at an applied field of 10 V/μm. The dark current in the p-i-n device is the lowest at approximately 0.01 pA mm−2 at an applied field of 10 V μm−1. Experiments have been carried out by subjecting the detector to a staircase voltage-time profile during the voltage application (turn-on) and a staircase voltage ramp-down during the turning-off of the bias voltage. Step-voltage ramp-up and step-voltage ramp-down current transient are typical of expected dark current transient behavior in a semiconductor with traps in which carriers are captured and released from various trap centers in the bandgap. The dark current transients are qualitatively similar to those expected from a capacitor in parallel with a large resistor and both in series with a much smaller resistor. Current transients during charging and discharging experiments were integrated to find how much of the injected charge is released during discharge experiments. It is shown that the majority of this trapped charge is stored in the n-type and p-type blocking layers, near the contacts. The trapped carriers in the i-layer represent a very small portion. The evolution of the dark current upon single and repeated x-ray exposure has also been examined in n-i and p-i-n devices. Right after the cessation of irradiation, there is an excess or residual dark current whose magnitude is roughly ∼20 times higher in p-i-n and about ∼2 times higher in the case of n-i under an exposure of 3.36 R and a mean photon energy of 34.2 keV. The absorbed dose is 1.53 Gy. The excess dark current has a fast decay component with a time constant ∼10 s and a slow component with a time constant ∼100 s. It is shown that the decay in the irradiation induced excess dark current is very similar to the initial dark current. There is no permanent change in the dark current, and within a few hundred seconds, the dark current reaches the same level as that in the unexposed detector. The experimental results in this work highlight the distinct advantages of p-i-n and n-i-type a-Se multilayer structures in x-ray detection applications.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,024
Score d'incertitude au seuil0,743

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,004
Tête enseignante GPT0,212
Écart entre enseignants0,208 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle