Training of deep convolutional neural nets to extract radiomic signatures of tumors

2019· article· en· W2975022009 sur OpenAlexaff
Jiwon Kim, Sophia Seo, Saeed Ashrafinia, Arman Rahmim, Vesna Sossi, Ivan S. Klyuzhin

Notice bibliographique

Revuenon disponible
Typearticle
Langueen
DomaineMedicine
ThématiqueRadiomics and Machine Learning in Medical Imaging
Établissements canadiensUniversity of British Columbia
Organismes subventionnairesnon disponible
Mots-clésConvolutional neural networkArtificial intelligenceVoxelPattern recognition (psychology)Computer scienceHistogramRadiomicsFeature (linguistics)Minimum bounding boxDeep learningImage (mathematics)Process (computing)
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

406 Objectives: Radiomics-based analysis of FDG PET images has been shown to improve the assessment and prediction of tumor growth rate, response to treatment and other patient outcomes [1]. An alternative new approach to image analysis involves the use of convolutional neural networks (CNNs), wherein relevant image features are learned implicitly and automatically in the process of network training [2]; this is in contrast to radiomics analyses, where the features are “hand-crafted” and are explicitly computed (EC). Although CNNs represent a more general approach, it is not clear whether the implicitly learned features may, or have the ability to include radiomics features (RFs) as a subset. If this is the case, CNN-based approaches may eventually obviate the use of EC RFs. Further, the use of CNNs instead of RFs may completely eliminate the need for feature selection and tumor delineation, enabling high-throughput data analyses. Thus, our objective was to test whether CNNs can learn to act similarly to several commonly used RFs. Using a set of simulated and real FDG PET images of tumors, we train the CNNs to estimate the values of RFs from the images without the explicit computation. We then compare the values of the CNN-estimated and EC features. Methods: Using a stochastic volumetric model for tumor growth, 2000 FDG images of tumors confined to a bounding box (BB) were simulated (40x40x40 voxels, voxel size 2.0 mm), and 10 RFs (3 x morphology, 4 x intensity histogram, 3 x texture features) were computed for each image using the SERA library [3] (compliant with the Image Biomarker Standardization Initiative, IBSI [4]). A 3D CNN with 4 convolutional layers, and a total of 164 filters, was implemented in Python using the Keras library with TensorFlow backend (https://www.keras.io). The mean absolute error was the optimized loss function. The CNN was trained to automatically estimate the values each of the 10 RFs for each image; 1900 of images were used for training, and 100 were used for testing, to compare the CNN-estimated values to the EC feature values. We also used a secondary test set comprised of 133 real tumor images, obtained from the head and neck PET/CT imaging study [5] publicly available at the Cancer Imaging Archive. The tumors were cropped to a BB, and the images were resampled to yield similar image size to the simulated image set. Results: After the training procedure, on the simulated test set the CNN was able to estimate the values of most EC RFs with 10-20% error (relative to the range). In the morphology group, the errors were 3.8% for volume, 12.0% for compactness, 15.7% for flatness. In the intensity group, the errors were 13.7% for the mean, 15.4% for variance, 12.3% for skewness, and 13.1% for kurtosis. In the texture group, the error was 10.6% for GLCM contrast, 13.4% for cluster tendency, and 21.7% for angular momentum. With all features, the difference between the CNN-estimated and EC feature values were statistically insignificant (two-sample t-test), and the correlation between the feature values was highly significant (p<0.01). On the real image test set, we observed higher error rates, on the order of 20-30%; however, with all but one feature (angular momentum), there was a significant correlation between the CNN-estimated and EC features (p<0.01). Conclusions: Our results suggest that CNNs can be trained to act similarly to several widely used RFs. While the accuracy of CNN-based estimates varied between the features, in general, the CNN showed a good propensity for learning. Thus, it is likely that with more complex network architectures and training data, features can be estimated more accurately. While a greater number of RFs need to be similarly tested in the future, these initial experiments provide first evidence that, given the sufficient quality and quantity of the training data, the CNNs indeed represent a more general approach to feature extraction, and may potentially replace radiomics-based analyses without compromising the descriptive thoroughness.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,731
Score d'incertitude au seuil0,909

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,014
Tête enseignante GPT0,290
Écart entre enseignants0,277 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations3
Publié2019
Routes d'admission1
Résumé présentoui

Explorer davantage

Même sujetRadiomics and Machine Learning in Medical ImagingTravaux en français237 207