Wrist-Based Accelerometers and Visual Analog Scales as Outcome Measures for Shoulder Activity During Daily Living in Patients With Rotator Cuff Tendinopathy: Instrument Validation Study
Notice bibliographique
Résumé
BACKGROUND: Shoulder pain secondary to rotator cuff tendinopathy affects a large proportion of patients in orthopedic surgery practices. Corticosteroid injections are a common intervention proposed for these patients. The clinical evaluation of a response to corticosteroid injections is usually based only on the patient's self-evaluation of his function, activity, and pain by multiple questionnaires with varying metrological qualities. Objective measures of upper extremity functions are lacking, but wearable sensors are emerging as potential tools to assess upper extremity function and activity. OBJECTIVE: This study aimed (1) to evaluate and compare test-retest reliability and sensitivity to change of known clinical assessments of shoulder function to wrist-based accelerometer measures and visual analog scales (VAS) of shoulder activity during daily living in patients with rotator cuff tendinopathy convergent validity and (2) to determine the acceptability and compliance of using wrist-based wearable sensors. METHODS: A total of 38 patients affected by rotator cuff tendinopathy wore wrist accelerometers on the affected side for a total of 5 weeks. Western Ontario Rotator Cuff (WORC) index; Short version of the Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH); and clinical examination (range of motion and strength) were performed the week before the corticosteroid injections, the day of the corticosteroid injections, and 2 and 4 weeks after the corticosteroid injections. Daily Single Assessment Numeric Evaluation (SANE) and VAS were filled by participants to record shoulder pain and activity. Accelerometer data were processed to extract daily upper extremity activity in the form of active time; activity counts; and ratio of low-intensity activities, medium-intensity activities, and high-intensity activities. RESULTS: Daily pain measured using VAS and SANE correlated well with the WORC and QuickDASH questionnaires (r=0.564-0.815) but not with accelerometry measures, amplitude, and strength. Daily activity measured with VAS had good correlation with active time (r=0.484, P=.02). All questionnaires had excellent test-retest reliability at 1 week before corticosteroid injections (intraclass correlation coefficient [ICC]=0.883-0.950). Acceptable reliability was observed with accelerometry (ICC=0.621-0.724), apart from low-intensity activities (ICC=0.104). Sensitivity to change was excellent at 2 and 4 weeks for all questionnaires (standardized response mean=1.039-2.094) except for activity VAS (standardized response mean=0.50). Accelerometry measures had low sensitivity to change at 2 weeks, but excellent sensitivity at 4 weeks (standardized response mean=0.803-1.032). CONCLUSIONS: Daily pain VAS and SANE had good correlation with the validated questionnaires, excellent reliability at 1 week, and excellent sensitivity to change at 2 and 4 weeks. Daily activity VAS and accelerometry-derived active time correlated well together. Activity VAS had excellent reliability, but moderate sensitivity to change. Accelerometry measures had moderate reliability and acceptable sensitivity to change at 4 weeks.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,014 | 0,025 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».