Evaluation of the Adoption of a Connected Device to Monitor and improve patient’s adherence and persistence to therapy using real-world data
Notice bibliographique
Résumé
Background The HealthBeaconTM is a smart sharps bin for patients who self-inject medications at home. It is digitally connected and programmed with a patient’s medication schedule and uses customized reminders to help them start and stay on track with their medication. The HealthBeacon device was launched in May 2015; since then, it has been used by 8000+ patients and has tracked 250,000+ injections across 11 markets. The HealthBeacon is designed to be passive. The patient is not asked to do anything; the device captures the act of disposal which is a highly accurate method for measuring drug adherence. Several studies on the adoption of self-tracking devices have found that the percentages of people who stopped using their device within relative short-term follow up periods may vary between 33-75%. A behavioral analysis was completed to determine if the patient-centric design of HealthBeacon technology can overcome barriers to patient adoption and improve persistence to therapy. Objective The objective was to evaluate the adoption of a connected device to monitor and improve patient adherence and persistence to therapy. Methods For the purpose of the study the patients were classified into two categories. 1) If all conditions outlined below were met, the patient “adopted” the technology: A) Patient consented to support program; B) HealthBeacon was delivered and established in the home; C) Patient utilized the technology correctly; D) Technology successfully tracked injections and communicated with HealthBeacon platform; E) Patient remains on HealthBeacon achieving high persistence to medication or continued until treatment completion. 2) If any of the following circumstances arose, the patient was considered as “rejected” as they failed to adopt the technology: A) Upon introduction to HealthBeacon the patient requested a regular sharps bin; B) Patient never disposed an injection into the HealthBeacon; C) Patient has not interacted with the device for 90+ days; D) Patient accepted the HealthBeacon initially but returned it for reasons other than their treatment ending Results Data were measured over a 24-month period from May 2017 to May 2019 for the 756 patients were involved in the study; 584 (77%) of the patients adopted the technology and 172 (23%) rejected it. Of the patients that adopted, 478 (82%) continue to utilize the technology and 106 (18%) are no longer active. The reason for stopping was associated with their treatment ending rather than an adoption issue. Of the 172 patients (23%) rejected the technology, 26 (15%) requested a standard sharps bin after receiving the introduction; 45 (26%) accepted the HealthBeacon but never disposed an injection into it; 86 (50%) used the HealthBeacon initially but had not interacted with it for 90+ days; 2 (1%) rejected it due to a technical issue; and 13 (8%) accepted it initially but reported that they prefer to manage adherence on their own. Conclusions With almost 80% of patients adopting the technology, and 82% of the adopters persisting, this study demonstrates that patient-centered design that deploys passive adherence monitoring can overcome barriers to adoption of technology.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».