A Deep Learning Approach for Managing Medical Consumable Materials in Intensive Care Units via Convolutional Neural Networks: Technical Proof-of-Concept Study
Notice bibliographique
Résumé
BACKGROUND: High numbers of consumable medical materials (eg, sterile needles and swabs) are used during the daily routine of intensive care units (ICUs) worldwide. Although medical consumables largely contribute to total ICU hospital expenditure, many hospitals do not track the individual use of materials. Current tracking solutions meeting the specific requirements of the medical environment, like barcodes or radio frequency identification, require specialized material preparation and high infrastructure investment. This impedes the accurate prediction of consumption, leads to high storage maintenance costs caused by large inventories, and hinders scientific work due to inaccurate documentation. Thus, new cost-effective and contactless methods for object detection are urgently needed. OBJECTIVE: The goal of this work was to develop and evaluate a contactless visual recognition system for tracking medical consumable materials in ICUs using a deep learning approach on a distributed client-server architecture. METHODS: We developed Consumabot, a novel client-server optical recognition system for medical consumables, based on the convolutional neural network model MobileNet implemented in Tensorflow. The software was designed to run on single-board computer platforms as a detection unit. The system was trained to recognize 20 different materials in the ICU, while 100 sample images of each consumable material were provided. We assessed the top-1 recognition rates in the context of different real-world ICU settings: materials presented to the system without visual obstruction, 50% covered materials, and scenarios of multiple items. We further performed an analysis of variance with repeated measures to quantify the effect of adverse real-world circumstances. RESULTS: Consumabot reached a >99% reliability of recognition after about 60 steps of training and 150 steps of validation. A desirable low cross entropy of <0.03 was reached for the training set after about 100 iteration steps and after 170 steps for the validation set. The system showed a high top-1 mean recognition accuracy in a real-world scenario of 0.85 (SD 0.11) for objects presented to the system without visual obstruction. Recognition accuracy was lower, but still acceptable, in scenarios where the objects were 50% covered (P<.001; mean recognition accuracy 0.71; SD 0.13) or multiple objects of the target group were present (P=.01; mean recognition accuracy 0.78; SD 0.11), compared to a nonobstructed view. The approach met the criteria of absence of explicit labeling (eg, barcodes, radio frequency labeling) while maintaining a high standard for quality and hygiene with minimal consumption of resources (eg, cost, time, training, and computational power). CONCLUSIONS: Using a convolutional neural network architecture, Consumabot consistently achieved good results in the classification of consumables and thus is a feasible way to recognize and register medical consumables directly to a hospital's electronic health record. The system shows limitations when the materials are partially covered, therefore identifying characteristics of the consumables are not presented to the system. Further development of the assessment in different medical circumstances is needed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».