Associations Between Heart Rate Variability Measured With a Wrist-Worn Sensor and Older Adults’ Physical Function: Observational Study
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
BACKGROUND: Heart rate variability (HRV), or variation in beat-to-beat intervals of the heart, is a quantitative measure of autonomic regulation of the cardiovascular system. Low HRV derived from electrocardiogram (ECG) recordings is reported to be related to physical frailty in older adults. Recent advances in wearable technology offer opportunities to more easily integrate monitoring of HRV into regular clinical geriatric health assessments. However, signals obtained from ECG versus wearable photoplethysmography (PPG) devices are different, and a critical first step preceding their widespread use is to determine whether HRV metrics derived from PPG devices also relate to older adults' physical function. OBJECTIVE: This study aimed to investigate associations between HRV measured with a wrist-worn PPG device, the Empatica E4 sensor, and validated clinical measures of both objective and self-reported physical function in a cohort of older adults living independently within a continuing care senior housing community. Our primary hypothesis was that lower HRV would be associated with lower physical function. In addition, we expected that HRV would explain a significant proportion of variance in measures of physical health status. METHODS: We evaluated 77 participants from an ongoing study of older adults aged between 65 and 95 years. The assessments encompassed a thorough examination of domains typically included in a geriatric health evaluation. We collected HRV data with the Empatica E4 device and examined bivariate correlations between HRV quantified with the triangular index (HRV TI) and 3 widely used and validated measures of physical functioning-the Short Physical Performance Battery (SPPB), Timed Up and Go (TUG), and Medical Outcomes Study Short Form 36 (SF-36) physical composite scores. We further investigated the additional predictive power of HRV TI on physical health status, as characterized by SF-36 physical composite scores and Cumulative Illness Rating Scale for Geriatrics (CIRS-G) scores, using generalized estimating equation regression analyses with backward elimination. RESULTS: =0.33 vs 0.17 without HRV). CONCLUSIONS: The HRV TI measured with a relatively novel wrist-worn PPG device was related to both objective (SPPB and TUG) and self-reported (SF-36 physical composite) measures of physical function. In addition, the HRV TI explained additional variance in self-reported physical function and cumulative illness severity beyond traditionally measured aspects of physical health. Future steps include longitudinal tracking of changes in both HRV and physical function, which will add important insights regarding the predictive value of HRV as a biomarker of physical health in older adults.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle