Reproducibility and Application of the Gaze and Movement Assessment (GaMA)
Notice bibliographique
Résumé
Introduction: State-of-the-art upper limb prosthetic devices are complex, with multi-articulating hands that can open and close on user command. These so-called myoelectric prostheses harness the signals of a user’s residual muscles to trigger a desired function, such as grasping an object. Despite functional advancements, myoelectric prostheses still have limited dexterity and lack sensory feedback. As such, users exhibit compensatory arm and trunk movements and allocate increased visual attention during device-object interactions. A standardized and quantitative measurement protocol that assesses the movement quality of prosthetic device users has yet to be adopted by researchers and clinicians, despite the motivation to improve function. One method of evaluating upper limb function, with relevance to prosthesis use, is through assessment of hand movement, angular joint kinematics, and eye gaze measures. These measures can be derived from data that are commonly collected using optical motion capture and eye tracking technologies. Motion capture data can be used to analyze upper limb motion and hand-object interactions, and simultaneously collected eye tracking data can facilitate analysis of hand-eye coordination. Assessments reliant on specialized data capture technologies such as these, however, lack standardized protocols, are not necessarily generalizable to activities of daily living (ADLs), and risk becoming obsolete. Background: A collaborative group of researchers at the University of Alberta has developed the Gaze and Movement Assessment (GaMA) protocol to address the need for standardized outcome performance measures that are representative of ADLs and achievable by individuals both with and without upper limb mobility restrictions. GaMA encompasses two standardized functional upper limb tasks and analysis software. This software requires a standardized data set of synchronized motion and eye data coordinates as input, and outputs hand movement, angular joint kinematic, and eye gaze measures. Although GaMA’s input has been collected using optical motion capture and state-of-the-art eye tracking technologies, the protocol is amenable to future advances in data capture solutions. Objectives: The first objective of this thesis was to determine if GaMA is reproducible – that is, whether GaMA could be used to obtain the same hand movement, angular joint kinematic, and eye gaze measures when testing two independent groups of non-disabled participants, at different research sites equipped with different data capture technologies, and by different raters. With the reproducibility of GaMA established, the second objective of this thesis was to use this assessment protocol to test the assumption that movement measures from actual myoelectric users are comparable to those of non-disabled individuals wearing a simulated prosthetic device. Methods: To accomplish the first objective, twenty non-disabled adults performed GaMA’s two functional tasks: the Pasta Box Transfer Task, which required participants to move a box of pasta to shelves of different heights; and the Cup Transfer Task, which required the same participants to move deformable, filled cups over a partition at table-top height. Participants’ upper body and eye movements were recorded using optical motion capture and eye tracking technologies, respectively. GaMA’s analysis software provided measures of hand movement, angular joint kinematics, and eye gaze. These measures were then compared to those from twenty non-disabled adults who had previously performed GaMA’s functional tasks at a different site. To accomplish the second objective of this thesis, three participants completed GaMA’s Pasta Box Transfer Task using their custom-fitted myoelectric prosthesis. Motion capture methods were followed for data acquisition, and GaMA’s software was used to derive hand movement and angular joint kinematic measures. Resulting performance metrics, end effector movements, and angular kinematics were compared to those from an already established data set, collected from twelve non-disabled participants wearing a simulated prosthesis at a different site. Results: The research conducted in this thesis concluded that GaMA is reproducible and can serve as a quantitative assessment tool for individuals both with and without sensory-motor impairment of the upper limb. Furthermore, it supports the notion that non-disabled individuals wearing a simulated prosthesis can act as substitutes for actual prosthesis users in research and expands the potential to compare data sets across different sites. Recommendation: Given that GaMA has been shown to be reproducible, it should be promoted as a measurement protocol for use in ongoing upper limb prosthesis research, inter-site research comparisons, and considered as a means of merging data sets to overcome sample size limitations of research participants with amputations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,092 | 0,123 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,001 | 0,002 |
| Bibliométrie | 0,003 | 0,002 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,002 | 0,001 |
| Science ouverte | 0,002 | 0,003 |
| Intégrité de la recherche | 0,002 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».