Minimally invasive flap compared to a trapezoidal flap in lateral approach maxillary sinus elevation procedures: Four-month post-loading results from a split-mouth randomised controlled trial.
Notice bibliographique
Résumé
PURPOSE: To test a minimally invasive flap in the lateral approach for maxillary sinus floor elevation when compared to a trapezoidal flap. MATERIALS AND METHODS: Each patient received a bilateral sinus elevation procedure based on two different randomly allocated surgical approaches according to a split-mouth design: in the test side, a horizontal incision at mucogingival line was realised; in the control side, a trapezoidal flap was elevated to prepare the lateral window. Each sinus was filled using deproteinised bovine bone and the window covered with a collagen membrane. Implants were inserted according to a two-stage technique 6 months after sinus elevation procedures, submerged and then loaded after 6 months with definitive screw-retained metal-ceramic prostheses. Patients were followed up to 4 months post-loading. Outcome measures included: implant and prosthesis failures, complications, peri-implant marginal bone level changes, residual bone height and width, recorded before sinus augmentation and 180 days post-intervention by computed tomography (CT) scans, surgical times and patient discomfort data, assessed using a visual analogue scale (VAS) diagram for each treated side at 1, 7, 14 and 30 days of follow-up. RESULTS: Seventeen patients were enrolled in this trial and none dropped out. Five completely edentulous patients were treated with full-arch prosthetic restorations (Toronto dental prosthesis) and 12 patients with partial metal-ceramic screw-retained prostheses. In total 72 implants were inserted, 37 in the test group and 35 in the control group. No prosthesis or implant failures occurred. A total of seven patients showed complications: five of them had complications in both test and control sides. Eight complications were detected in each group. During maxillary sinus elevation procedures, nine interventions (four from the test group and five from the control group) were affected by intrasurgical complications (six membrane perforations and three severe bleedings); post-surgical complications occurred to three patients (one submucosal emphysema in a patient from the test group, one wound dehiscence and a graft infection both recorded in the control group); a total of four implants in two patients in the test group, versus three implants from one patient in the control group showed peri-implant mucositis. There were no statistically significant differences in complications between the two groups (P = 1.00; 95% confidence interval [CI]: 0.15-3.11). Patients from the control group, at 4 months after loading, lost on average 0.53 mm (standard deviation [SD] 0.27; 95% CI: 0.40-0.65), and patients from the test group lost on average 0.66 mm (SD 0.27; 95% CI: 0.53-0.78); the difference was not statistically significant (mean difference: 0.07 mm; SD 0.34; 95% CI: -0.03-0.17; P = 0.102). Significant values for bone augmentation in height, 9.26 mm (SD 1.46; 95% CI: 8.56-9.95) in the test group and 9.38 mm (SD 1.95; 95% CI: 8.45-10.30) in the control group, and width, 1.68 mm (SD 1.04; 95% CI: 1.18-2.20) in the test group and 1.60 mm (SD 1.27; 95% CI: 0.99-2.20) in the control group, were found from the 180-day CT scans. No statistically significant differences were detected between the two groups, either for the bone augmentation data (difference: 0.27 mm; 95% CI: 0.15-0.38; P = 0.60) or for the bone width values (difference: 0.02 mm; 95% CI: 0.07-0.11; P = 0.67). A significant reduction in the total surgical time was found in the test group (mean difference: 6.64 minutes; SD 4.32; 95% CI: 4.58-8.69), with the difference being statistically significant (P = 0.009). Evaluation of patients' postoperative discomfort showed a significant preference for the test procedure: at 1 day the VAS value was 4 (interquartile range [IQR] 2 to 5) in the test group; in the control group the VAS score was 5 (IQR 4 to 8). The intergroup difference was statistically significant (P = 0.002). At the 7-day follow-up, the VAS value was 1 in the test group (IQR 0 to 3) and 3 in the control group (IQR 0 to 7), this difference was statistically significant (P = 0.003). No differences were detected at 14 and 30 days (P > 0.05). CONCLUSIONS: A minimally invasive approach to access the sinus cavity can be as successful as a conventional trapezoidal flap in maxillary sinus floor elevations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,005 | 0,002 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,002 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».